Viessmann VITODENS 200-W Service Instructions Manual page 80

Wall mounted gas condensing boiler natural gas and lpg version
Table of Contents

Advertisement

Code 2
Heating circuit 1, heating circuit 2, heating...
Coding in the delivered condition
b0:0
With remote control:
Heating mode/reduced
mode: Weather-compen-
sated (only for weather-
compensated control
units; change the code
only for the heating circuit
with mixer)
b2:8
With remote control and
for the heating circuit,
operation with room tem-
perature hook-up must be
programmed: Room influ-
ence factor 8 (only for
weather-compensated
control units; change the
code only for the heating
circuit with mixer)
b5:0
With remote control: No
room temperature-
dependent heating circuit
pump logic function (only
for weather-compensa-
ted control units; change
the code only for the heat-
ing circuit with mixer)
Parameter
With heating circuit pump logic function:
address b5:...
Heating circuit pump "OFF"
1
RT
actual
2
RT
actual
3
RT
actual
4
RT
actual
5
RT
actual
6
RT
actual
7
RT
actual
8
RT
actual
80
Possible change
b0:1
b0:2
b0:3
b2:0
b2:1
to
b2:64
b5:1
to
b5:8
> RT
+ 5 K
set
> RT
+ 4 K
set
> RT
+ 3 K
set
> RT
+ 2 K
set
> RT
+ 1 K
set
> RT
set
> RT
- 1 K
set
> RT
- 2 K
set
(cont.)
Heating mode: Weather-
compensated
Reduced mode: With room
temperature hook-up
Heating mode: With room
temperature hook-up
Reduced mode: Weather-
compensated
Heating mode/reduced
mode: With room tempera-
ture hook-up
Without room influence
Room influence factor
adjustable from 1 to 64
Heating circuit pump logic
function, see the following
table:
Heating circuit pump "ON"
RT
< RT
+ 4 K
actual
set
RT
< RT
+ 3 K
actual
set
RT
< RT
+ 2 K
actual
set
RT
< RT
+ 1 K
actual
set
RT
< RT
actual
set
RT
< RT
- 1 K
actual
set
RT
< RT
- 2 K
actual
set
RT
< RT
- 3 K
actual
set