Viessmann VITODENS 200-W Service Instructions Manual page 99

Wall mounted gas condensing boiler natural gas and lpg version
Table of Contents

Advertisement

Fault codes
(cont.)
Dis-
Const.
Weath.-
played
comp.
fault
code
98
X
X
99
X
X
9A
X
X
9b
X
X
9C
X
X
9E
X
X
9F
X
X
A6
X
X
A7
X
System char-
Cause
acteristics
Control mode
Lead broken,
temperature
sensor /
Control mode
Lead broken,
temperature
sensor aÖ
No DHW heat-
Lead break,
ing
collector tem-
perature sen-
sor
Control mode
Lead break,
cylinder tem-
perature sen-
sor
No DHW heat-
Lead break,
ing
cylinder tem-
perature sen-
sor
Control mode
No flow rate
in the collec-
tor circuit or
flow rate too
low, or tem-
perature lim-
iter has
responded
Control mode
Solar control
module or
Vitosolic
faulty
Control mode
Impressed
current anode
faulty
Control mode
Programming
as per deliv-
unit faulty
ered condition
Troubleshooting
Measures
Check sensor /
on the solar control
module
Check sensor aÖ
on the solar control
module
Check temperature
sensor & on the
solar control mod-
ule or the Vitosolic
sensor
Check temperature
sensor at connec-
tion S3 to the
Vitosolic 100
Check temperature
sensor % on the
solar control mod-
ule or the Vitosolic
sensor
Check solar circuit
pump and solar cir-
cuit. Acknowledge
fault message
Replace solar con-
trol module or
Vitosolic
Replace
impressed current
anode
Replace program-
ming unit