Viessmann VITODENS 200-W Service Instructions Manual page 104

Wall mounted gas condensing boiler natural gas and lpg version
Table of Contents

Advertisement

Troubleshooting
Fault codes
(cont.)
Dis-
Const.
Weath.-
played
comp.
fault
code
dF
X
E0
X
E4
X
X
E5
X
X
E8
X
X
E9
X
X
EA
X
X
104
System char-
Cause
acteristics
Control mode
Lead break,
without room
room temper-
influence
ature sensor,
heating circuit
3 (with mixer)
Control mode
Fault external
LON sub-
scriber
Burner blocked Fault, supply
voltage 24 V
Burner blocked Fault, flame
amplifier
Burner in a fault
The ionisa-
state
tion current
lies outside
the permissi-
ble range
Burner in a fault
The ionisa-
state
tion current
lies outside
the permissi-
ble range dur-
ing calibra-
tion
Burner in a fault
The ionisa-
state
tion current
lies outside
the permissi-
ble range dur-
ing calibra-
tion
Measures
Check room tem-
perature sensor for
heating circuit 3
and remote control
settings (see
page 132)
Check connections
and LON subscrib-
ers
Replace the control
unit.
Replace the control
unit.
Check the ionisa-
tion electrode and
cable.
Press reset button
R.
Check the ionisa-
tion electrode and
cable.
Check the flue gas
system for tight-
ness.
Press reset button
R.
Check the ionisa-
tion electrode and
cable.
Press reset button
R.