Socket ScanAPI Reference
14.15 Property kSktScanPropIdRestoreFactoryDefaultsDevice
This property sets the connected device to its factory defaults. The device will
power down once the factory defaults have been applied and the Set Complete has
been sent.
Parameter type
Get
Not applicable
Version
ScanAPI Interface Version
14.16 Property kSktScanPropIdSetPowerOffDevice
This property turns the power off from the device causing it to disconnect.
This property can only be used in a Set operation and doesn't have any parameters.
This is one of the rare cases where a Set Complete might not be received before the
device drops the connection. From the application point of view, the device removal
might come before the Set Complete timeout error. If the application closes right
away the device upon reception of the device removal event, the Set Complete
timeout error will never be received by the application.
Parameter type
Get
Not applicable
Version
ScanAPI Interface Version
14.17 Property kSktScanPropIdButtonStatusDevice
This property gets the button status of the connected device.
The button status is coded in one byte as a bit field indicating the status of each
button on the device.
A set of macros can be used in order to retrieve the status of a particular button. The
macro returns a Boolean to indicate if the button is pressed (true) or released (false)
or, in the case of the Series 9 Ring Scanner, it is detached (true) or attached (false).
The macro definitions can be found in paragraph 11.6.3 Buttons Event.
© 2013 Socket Mobile, Inc.
Get Complete
Not applicable
Get Complete
Not applicable
Set
None
1.0.0 or higher
Set
None
1.0.0 or higher
Set Complete
None
Set Complete
None
98/152
Need help?
Do you have a question about the ScanAPI and is the answer not in the manual?