Download Print this page

Property Ksktscanpropiddataconfirmationmode - Socket ScanAPI Reference Manual

Advertisement

Socket ScanAPI Reference
delete[]ScanObj.Property.String.pValue;
}
else
{
// ... handle the error
}
NOTE:
Changing the COM port ScanAPI is listening will cause ScanAPI to shutdown any
active connections and restart its listener thread on the newly specified COM port. If
the COM port doesn't exist or cannot be opened an error
(ESKT_UNABLEOPENDEVICE) is generated and sent to the application as an
asynchronous message. ScanAPI generates an error (ESKT_NOTHINGTOLISTEN) if
no COM port can be successfully open.
C/C++:
The configuration define can be found in the SktScanPropIds.h file.
Java:
The configuration define can be found in
com.SocketMobile.ScanAPI.ISktScanProperty.values.configuration.
C#:
The configuration define can be found in
ScanAPI.ISktScanProperty.values.configuration
Objective C:
The configuration define can be found in the SktScanPropIds.h file.
Parameter type
Get
String
Version
ScanAPI Interface Version

13.5 Property kSktScanPropIdDataConfirmationMode

This property is used to read or modify the Data Confirmation feature.
The Data Confirmation feature controls how decoded data should be acknowledged.
Decoded data can be acknowledged at three different locations; locally on the
scanner device, remotely on the host at the ScanAPI level or at the application level.
The advantage of acknowledging the data locally on the device is speed, but the
operator doesn't know for sure the data has arrived at the application level. The
© 2013 Socket Mobile, Inc.