AOpen Fortress 1120 User Manual page 54

Table of Contents

Advertisement

42
This support bracket must be mounted level with the lower edge of
the device. The support bracket is used for the rear fixing of the left
carrier rail.
1
Review the installation instructions in the DataCenter Rack
documentation.
2
Mark the position of the attachment points of the server on the
support uprights (1 HU).
3
Mount the support bracket using two screws and cage nuts at the
appropriate height on the rear left support upright.
Note: If required, you can mount one additional cable clip for
vertical cable routing.
To fasten the carrier rails, no cage nuts are necessary since the rails
are equipped with threaded holes.
To mount the carrier rails, mounting brackets must be installed in
the support uprights and/or in the support bracket. To do this:
a
Place the mounting brackets in the holes of the support
uprights and/or of the support bracket at the marked
attachment points.
b
Secure the two carrier rails in the rack at the left and right
support uprights or at the support bracket.
Appendix A — System rack installation