118
AXCESS Programming
System Send_Commands (Cont.)
Command
'PAGE-<page name>'
'PKEYP-<number string>'
'RESET'
'SETUP'
'SLEEP'
'TPAGEOFF'
Description
Flip to page with specified page name.
page name = 1-20 characters
Example:
SEND_COMMAND TP,'PAGE-MAIN PAGE'
Flips the touch panel to the page named MAIN PAGE.
Display asterisks (*) for keypad entries.
number string = 0-9999
Example:
SEND_COMMAND TP,'PKEYP-1988'
Displays the touch panel keypad with **** instead of 1988.
Clear panel status (same as power up). Data stored in memory is
not cleared.
Example:
SEND_COMMAND TP,'RESET'
Resets the touch panel.
Go to the Setup page.
Example:
SEND_COMMAND TP,'SETUP'
Flips the touch panel to the Setup page.
Switch the touch panel to screen saver mode.
Example:
SEND_COMMAND TP,'SLEEP'
Activates the screen saver mode.
Deactivate page tracking.
Example:
SEND_COMMAND TP,'TPAGEOFF'
Deactivates the page tracking option.