Page 1
CB TEST Ref. Certificate No. CERTIFICATE SG-2634M1 IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME Issued by: TÜV SÜD PSB Pte Ltd Product: LCD Monitor Applicant: DIVA Laboratories Ltd. 7TH FL-8, 351 CHUNG Taiwan SHAN RD, SEC 2, CHUNG HO, TAIPEI HSIEN 235 TAIWAN...
Page 2
IEC SYSTEM FOR CONFORMITY Ref. Certificate No. TESTING TO STANDARDS FOR SAFETY OF ELECTRICAL SG-2634M1 EQUIPMENT (IECEE) CB SCHEME LUXON Systems Corporation NO. 161, Hsing Jen Road, Tamshui Taipei Hsien, Taiwan Additional information (if necessary) This CB Test Certificate is issued by the National Certification Body: TÜV SÜD PSB Pte Ltd 1 Science Park Drive, Singapore 118221 Signed by:...
CHUNG HO, TAIPEI HSIEN 235 TAIWAN Rating and principal 24V DC, 3.0A characteristics: Trade mark (if any): AG neovo Model/Type ER-192 reference: Additional information: Certificate SG-2634 issued 2006-11-30 is replaced by this version due to add model, trademark, alternate metal enclosure and base and alternate classification according to the degree of protection against ingress of water.
Page 4
IEC SYSTEM FOR CONFORMITY Ref. Certificate No. TESTING TO STANDARDS FOR SAFETY OF ELECTRICAL SG-2634M1/B1 EQUIPMENT (IECEE) CB SCHEME LUXON Systems Corporation NO. 161, Hsing Jen Road, Tamshui Taipei Hsien, Taiwan Additional information (if necessary) This CB Test Certificate is issued by the National Certification Body: TÜV SÜD PSB Pte Ltd 1 Science Park Drive, Singapore 118221 Signed by:...
Page 6
page 2 of 25 Report No. 55S072148/NCH/CZ Copy of marking plate See Appendix 11 to 12 of Test Report Ref. No.: 55S062732/NCH/CZ and Appendix 5 of this Test Report. TRF No. I6011__C TRF originator: UL...
page 3 of 25 Report No. 55S072148/NCH/CZ GENERAL INFORMATION Test item particulars (see also clause 5): Classification of installation and use ........: Portable Supply connection ..............: Output of external certified power adapter Accessories and detachables parts included in the evaluation None ....................
Page 8
The ”x” in the model designation can be A-Z to indicate different TFT panel supplier. ER-192 is similar to models: GOKx7yzMI & GODx7yzMI except for model designation , enclosure and base. (Refer to Appendix 6 for the identity declaration letter)
Page 9
B applied part concerning protection against electric shock. IPX2, only for model: ER-192. Classification according to the degree of protection (see separate test report) against ingress of water as detailed in the current edition of IEC 529 (see 6.1.1) ........:: Not applicable.
Page 10
Name and/or trademark of the manufacturer or DIVA supplier ..............: f) Model or type reference ........: GOD971xM , GOK971xM , ER-192 g) Rated supply voltages or voltage range(s) Number of phases ............ : Type of current ............: DC Symbol 417-5031 is used.
Page 11
page 7 of 25 Report No. 55S072148/NCH/CZ IEC 601 + Am. 1& 2 Clause Requirement + Test Result - Remark Verdict r) Anaesthetic-proof symbol: AP or APG ....: Not of category AP or APG. s) Dangerous voltage symbol No accessible high voltage terminal devices.
Page 12
page 8 of 25 Report No. 55S072148/NCH/CZ IEC 601 + Am. 1& 2 Clause Requirement + Test Result - Remark Verdict k) For permanently connected devices the supply Not permanently connected connections are clearly marked adjacent to the equipment. terminals (or in accompanying documents for small equipment) l) Statement for suitable wiring materials at Not permanently connected...
page 9 of 25 Report No. 55S072148/NCH/CZ IEC 601 + Am. 1& 2 Clause Requirement + Test Result - Remark Verdict a) In accordance with ISO ISO/R 32 No such device. b) Identification of connection point Indicator lights and push-buttons a) Red indicator lights used exclusively to indicate a warning of danger and/or a need for urgent action...
Page 14
page 10 of 25 Report No. 55S072148/NCH/CZ IEC 601 + Am. 1& 2 Clause Requirement + Test Result - Remark Verdict - include: indications of recognized accessories, detachable parts and materials, if the use of other parts or materials can degrade minimum safety - instructions concerning cleaning, preventive Provided in the user manual.
Page 15
page 11 of 25 Report No. 55S072148/NCH/CZ IEC 601 + Am. 1& 2 Clause Requirement + Test Result - Remark Verdict d) Environmental conditions for transport and Ambient: -20 C to +60 storage specified in accompanying documents Humidity: 10% to 90% and marked on packaging Air Pressure: 187 to 1060hPa was provided in the user...
page 12 of 25 Report No. 55S072148/NCH/CZ IEC 601 + Am. 1& 2 Clause Requirement + Test Result - Remark Verdict CONTINUOUS LEAKAGE CURRENTS AND PATIENT AUXILIARY CURRENTS 19.1b Leakage currents (see appended table 19) - earth leakage current - enclosure leakage current - patient leakage current No patient leakage current.
Page 17
Equipment or its parts with a mass of more than 20 kg is provided with: - suitable handling devices (grips etc.), or The weight of the equipment, ER-192 is 7.8 kg (< 20 kg). - instructions for lifting and handling during assembly 24.6b...
Page 18
page 14 of 25 Report No. 55S072148/NCH/CZ IEC 601 + Am. 1& 2 Clause Requirement + Test Result - Remark Verdict OVERFLOW, SPILLAGE, LEAKAGE, HUMIDITY, INGRESS OF LIQUIDS, CLEANING, STERILIZATION AND DISINFECTION 44.2 Equipment contain a liquid reservoir: - the equipment is electrically safe after 15% overfill No liquid reservoir inside the steadily over a period of 1 min equipment.
Page 19
page 15 of 25 Report No. 55S072148/NCH/CZ IEC 601 + Am. 1& 2 Clause Requirement + Test Result - Remark Verdict ABNORMAL OPERATION AND FAULT CONDITIONS 52.1 Equipment is so designed and manufactured that (see appended table 52) even in single fault condition no safety hazard as described under 52.4 exists (see 3.1 and Cl.
Page 20
page 16 of 25 Report No. 55S072148/NCH/CZ IEC 601 + Am. 1& 2 Clause Requirement + Test Result - Remark Verdict COMPONENTS AND GENERAL ASSEMBLY List of critical components (see appended table 56.1) 56.1b Ratings of components not in conflict with the The components are used conditions of use in equipment according to their rating.
Page 21
page 17 of 25 Report No. 55S072148/NCH/CZ IEC 601 + Am. 1& 2 Clause Requirement + Test Result - Remark Verdict a) Thermal cut-outs which have to be reset by a No thermal cut-out inside the soldering not fitted in equipment equipment.
Page 22
page 18 of 25 Report No. 55S072148/NCH/CZ IEC 601 + Am. 1& 2 Clause Requirement + Test Result - Remark Verdict Detachable indicating devices are prevented from incorrect connection without the use of tool 56.10c Stops are provided on rotating controls: - to prevent an unexpected change from No such device.
Page 23
Humidity Humidity (µA) (µA) Model: ER-192, with D/A inverter: TDK, P/N: TBD319LF-2, LCD panel: NEC, P/N: NL128102BC29 Figure 16, Earth Leakage ER, NC, S1 = 1, S5 = N ER, NC, S1 = 1, S5 = R ER, SFC, S1 = 0, S5 = N...
Page 24
page 20 of 25 Report No. 55S072148/NCH/CZ IEC 601 + Am. 1& 2 Clause Requirement + Test Result - Remark Verdict TABLE: dielectric strength Insulation under test Insulation type: (OP-operational / Reference Test Remarks (area from insulation BI-basic / SI-supplementary / voltage (V) voltage diagram)
Page 25
Ambient temperature . : 25.0 ºC, 24.7 ºC. Measured temperature Measuring location [ºC] Remarks (Limit) Model: ER-192, with Power Adapter: Lien, LE-0312B130W; D/A inverter: TDK, P/N: TBD319LF-2; LCD panel: NEC, P/N: NL128102BC29, Panel placed vertically Test Voltage 264V Measured Corrected Measured Corrected...
Page 26
Verdict TABLE: abnormal operation Test type, condition and clause reference Observed results Remarks Model: ER-192, with D/A inverter: TDK, P/N: TBD319LF-2, LCD panel: NEC, P/N: NL128102BC29, Panel placed vertically Ventilation openings blocked Unit operated normally. No hazard. Temperature data on: T1 coil (Adapter): 79.1 ºC...
Page 27
353 by 85 mm & IEC 60695-11- GOK971xMII) Enclosure and Various Various Metal, Base Material min. 0.81mm (for model: thick ER-192) Base Various Various Rated HB min. UL 746 with metal, (Harmonized overall 332 by with IEC 60707 210 by 420 mm, &...
Page 28
page 24 of 25 Report No. 55S072148/NCH/CZ Object/part No Manufacturer/ Type/model Technical data Standard Mark(s) of trademark conformity -Inverter NIA15/20EM- 130°C Transformer (T1- T68H002 Power Adapter Medi-Power AD-2480MB Input: 100-240 IEC 60601-1: TUV/R (CB Ref. Vac, 60/50Hz, 1988+A1+A2 Certificate 1A-0.5A, Class I No.:DE 2- Output: 24Vdc, 006195)
page 25 of 25 Report No. 55S072148/NCH/CZ SUMMARY OF CONTENTS: The equipment has been tested according to standard IEC 60601-1:1988 Second Edition + A1:1991 + A2:1995. All applicable tests according to the above specified standard(s) have been carried out. These tests fulfill the requirements of standard EN45001. This test report comprises 25 pages of CB Test Report and the following Attachments: Attachment # Description...
Page 30
Page A1 of A6 Ref. No.: 55S072148/NCH/CZ Appendix 1 External front view of LCD Monitor Model: ER-192 55S072148...
Page 31
Page A2 of A6 Ref. No.: 55S072148/NCH/CZ Appendix 2 External rear view of LCD Monitor Model: ER-192 55S072148...
Page 32
Page A3 of A6 Ref. No.: 55S072148/NCH/CZ Appendix 3 Internal views of LCD Monitor Model: ER-192 55S072148...
Page 33
Page A4 of A6 Ref. No.: 55S072148/NCH/CZ Appendix 4 PWB views of D/A inverter (TDK, P/N: TBD319LF-2) used in LCD Monitor Model: ER-192 55S072148 55S072148...
Page 34
Page A5 of A6 Ref. No.: 55S072148/NCH/CZ Appendix 5 Product Marking of LCD Monitor Model: ER-192 55S072148...
Page 35
Page A6 of A6 Ref. No.: 55S072148/NCH/CZ Appendix 6 Letter of Declaration by “DIVA Laboratories Ltd.” ----1 page as attached----...
Page 36
Declaration Letter Letter Date: 2007/10/17 We, DIVA Laboratories Ltd., have to explain and confirm to our models ER-192. ER-192 same as GOD971xMII and GOK971xMII ( x can be A~Z.) just enclosure different and add IPX2 for this enclosure. Best Regards Signature: John Liu Director / R&D Dept...
Need help?
Do you have a question about the ER-192 and is the answer not in the manual?
Questions and answers