ICP RS Series User Manual page 134

Icp controllers of the rs & rz series 32/64 bit 33/66 mhz pci ultra160 scsi raid controllers
Table of Contents

Advertisement

In this example there is one Array Drive in the FAIL
state. I.e., the Array Drive is still operating but no
longer redundant.
After pressing any key, ICPCON displays a list of
Array Drives which are candidates for this online
automatic repair. Note: Array Drives which have the
„ERROR" state are very critical and have lost 2 or
even more drives. These Array Drives cannot not be
repaired with this function. In such critical cases
the data integrity can longer be maintained. You
may call our technical support center for further
assistance.
After selecting the Array Drive, ICPCON
display the actual drive which has failed. In
this example it is the hard disk which forms
Logical Drive 5.
After confirmation, the failed drive has to be taken out and the new one has to be config-
ICPCON detects the new drive and expects a clearance to build this drive as a replacement
into the Array Drive.
After that the state of the Array Drive changes into „REBUILD", i.e. the missing data is re-
constructed out of the remaining data and the redundancy information.
134
ured on the same ID an
plugged in again.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents