1-16. AC Current Specifications

Table 1-16. 5720A Series II AC Current Specifications: 99 % Confidence Level
5720A
99%
99 % Confidence Level
Range
Resolution
Frequency
010 - 20
020 - 40
220 A
1 nA
040 - 1 k
01k - 5 k
05k - 10 k
010 - 20
020 - 40
2.2 mA
10 nA
040 - 1 k
01k - 5 k
05k - 10 k
010 - 20
020 - 40
22 mA
100 nA
040 - 1 k
01k - 5 k
05k - 10 k
010 - 20
020 - 40
220 mA
1 A
040 - 1 k
01k - 5 k
05k - 10 k
020 - 1 k
2.2 A
10 A
01 k - 5 k
05 k - 10 k
0
11 A
100 A
01 k - 5 k
05 k - 10 k
Note: Maximum output from the calibrator's terminals is 2.2 A. Uncertainty specifications for 220 A and 2.2 mA
ranges are increased by a factor of 1.3 plus 2 A when supplied through 5725A terminals. Specifications are
otherwise identical for all output locations.
Absolute Uncertainty
5 °C from calibration temperature
For fields strengths >0.4 V/m but 3 V/m,
24 Hours
90 Days
Hz
0260 + 20
0280 + 20
0170 + 12
0180 + 12
0120 + 10
0130 + 10
0300 + 15
0320 + 15
1000 + 80
1100 + 80
0260 + 50
0280 + 50
0170 + 40
0180 + 40
0120 + 40
0130 + 40
0210 + 130
0220 + 130
1000 + 800
1100 + 800
0260 + 500
0280 + 500
0170 + 400
0180 + 400
0120 + 400
0130 + 400
0210 + 700
0220 + 700
1000 + 6000
1100 + 6000
Hz
0260 + 5
0280 + 5
0170 + 4
0180 + 4
0120 + 3
0130 + 3
0210 + 4
0220 + 4
1000 + 12
1100 + 12
0290 + 40
0300 + 40
0440 + 100
0460 + 100
6000 + 200
7000 + 200
5725A Amplifier:
40 - 1 k
0370 + 170
0400 + 170
0800 + 380
0850 + 380
3000 + 750
3300 + 750
add 1 % of range.
180 Days
1 Year
(ppm output + nA)
0290 + 20
0300 + 20
0190 + 12
0200 + 12
0135 + 10
0140 + 10
0340 + 15
0350 + 15
1200 + 80
1300 + 80
0290 + 50
0300 + 50
0190 + 40
0200 + 40
0135 + 40
0140 + 40
0230 + 130
0240 + 130
1200 + 800
1300 + 800
0290 + 500
0300 + 500
0190 + 400
0200 + 400
0135 + 400
0140 + 400
0230 + 700
0240 + 700
1200 + 6000
1300 + 6000
(ppm output + A)
0290 + 5
0300 + 5
0190 + 4
0200 + 4
0135 + 3
0140 + 3
0230 + 4
0240 + 4
1200 + 12
1300 + 12
0310 + 40
0320 + 40
0480 + 100
0500 + 100
7500 + 200
8000 + 200
0440 + 170
0460 + 170
0900 + 380
0950 + 380
3500 + 750
3600 + 750
Introduction and Specifications

AC Current Specifications

Relative Uncertainty
1 °C
24 Hours
90 Days
(ppm output + nA)
0260 + 20
0280 + 20
0130 + 12
0150 + 12
0100 + 10
0110 + 10
0250 + 15
0280 + 15
0900 + 80
01000 + 80
0260 + 50
0280 + 50
0130 + 40
0150 + 40
0100 + 40
0110 + 40
0250 + 130
0280 + 130
0900 + 800
1000 + 800
0260 + 500
0280 + 500
0130 + 400
0150 + 400
0100 + 400
0110 + 400
0250 + 700
0280 + 700
0900 + 6000
1000 + 6000
(ppm output + A)
0260 + 5
0280 + 5
0130 + 4
0150 + 4
0100 + 3
0110 + 3
0250 + 4
0280 + 4
1000 + 12
0900 + 12
0300 + 40
0350 + 40
0500 + 100
0520 + 100
7000 + 200
6000 + 200
0300 + 170
0330 + 170
0700 + 380
0800 + 380
3200 + 750
2800 + 750
1