5725A
Instruction Manual
5720A
95%
95 % Confidence Level
Range
Resolution
220 A
2.2 mA
22 mA
220 mA
2.2 A
11 A
Note: Maximum output from the calibrator's terminals is 2.2 A. Uncertainty specifications for 220 A and
2.2 mA ranges are increased by 1.3 x plus 2 A when supplied through 5725A terminals. Specifications are
otherwise identical for all output locations.
1-24
Table 1-17. 5720A Series II AC Current Specifications: 95 % Confidence Level
Frequency
24 Hours
Hz
0210 + 16
010 - 20
0130 + 10
020 - 40
1 nA
0100 + 8
040 - 1 k
0240 + 12
01k - 5 k
0800 + 65
05k - 10 k
010 - 20
0210 + 40
020 - 40
0140 + 35
10 nA
040 - 1 k
0100 + 35
01k - 5 k
0170 + 110
05k - 10 k
0800 + 650
010 - 20
0210 + 400
020 - 40
0130 + 350
100 nA
040 - 1 k
0100 + 350
01k - 5 k
0170 + 550
0800 + 5000
05k - 10 k
Hz
0210 + 4
010 - 20
0130 + 3.5
020 - 40
0100 + 2.5
1 A
040 - 1 k
0170 + 3.5
01k - 5 k
0800 + 10
05k - 10 k
020 - 1 k
0230 + 35
10 A
01 k - 5 k
0350 + 80
05 k - 10 k
5000 + 160
5725A Amplifier:
0
40 - 1 k
0370 + 170
100 A
01 k - 5 k
0800 + 380
05 k - 10 k
3000 + 750
Absolute Uncertainty
5 °C from calibration temperature
For fields strengths >0.4 V/m but 3 V/m,
add 1 % of range.
90 Days
180 Days
(ppm output + nA)
0230 + 16
0240 + 16
0140 + 10
0150 + 10
0110 + 8
0115 + 8
0250 + 12
0270 + 12
0900 + 65
1000 + 65
0230 + 40
0240 + 40
0140 + 35
0150 + 35
0110 + 35
0115 + 35
0180 + 110
0190 + 110
0900 + 650
1000 + 650
0230 + 400
0240 + 400
0140 + 350
0150 + 350
0110 + 350
0115 + 350
0180 + 550
0190 + 550
0900 + 5000
1000 + 5000
(ppm output + A)
0230 + 4
0240 + 4
0140 + 3.5
0150 + 3.5
0110 + 2.5
0115 + 2.5
0180 + 3.5
0190 + 3.5
0900 + 10
1000 + 10
0240 + 35
0250 + 35
0390 + 80
0420 + 80
6000 + 160
6500 + 160
0400 + 170
0440 + 170
0850 + 380
0900 + 380
3300 + 750
3500 + 750
Relative Uncertainty
1 Year
24 Hours
(ppm output + nA)
0250 + 16
0210 + 16
0160 + 10
0110 + 10
0120 + 8
0080 + 8
0280 + 12
0200 + 12
1100 + 65
0700 + 65
0210 + 40
0250 + 40
0160 + 35
0110 + 35
0120 + 35
0080 + 35
0200 + 110
0200 + 110
1100 + 650
0700 + 650
0250 + 400
0210 + 400
0160 + 350
0110 + 350
0120 + 350
0080 + 350
0200 + 550
0200 + 550
1100 + 5000
0700 + 5000
(ppm output + A)
0250 + 4
0210 + 4
0160 + 3.5
0110 + 3.5
0120 + 2.5
0080 + 2.5
0200 + 3.5
0200 + 3.5
1100 + 10
0700 + 10
0260 + 35
0250 + 35
0450 + 80
0400 + 80
7000 + 160
5000 + 160
0460 + 170
0300 + 170
0950 + 380
0700 + 380
3600 + 750
2800 + 750
1 °C
90 Days
0230 + 16
0130 + 10
0090 + 8
0230 + 12
0800 + 65
0230 + 40
0130 + 35
0090 + 35
0230 + 110
0800 + 650
0230 + 400
0130 + 350
0090 + 350
0230 + 550
0800 + 5000
0230 + 4
0130 + 3.5
090 + 2.5
0230 + 3.5
0800 + 10
0300 + 35
0440 + 80
6000 + 160
0330 + 170
0800 + 380
3200 + 750

Hide quick links: