Ac Voltage Secondary Performance Specifications And Operating Characteristics - Fluke 5725A Instruction Manual

Fluke amplifier instruction manual
Hide thumbs Also See for 5725A:
Table of Contents

Advertisement

5725A
Instruction Manual
Table 1-8. AC Voltage Secondary Performance Specifications and Operating Characteristics
Range
Frequency
0010 - 20
0020 - 40
0040 - 20 k
2.2 mV
020 k - 50 k
050 k - 100 k
100 k - 300 k
300 k - 500 k
500 k - 1 M
0010 - 20
0020 - 40
0040 - 20 k
22 mV
020 k - 50 k
050 k - 100 k
100 k - 300 k
300 k - 500 k
500 k - 1 M
0010 - 20
0020 - 40
0040 - 20 k
220 mV
020 k - 50 k
050 k - 100 k
100 k - 300 k
300 k - 500 k
500 k - 1 M
0010 - 20
0020 - 40
0040 - 20 k
2.2 V
020 k - 50 k
050 k - 100 k
100 k - 300 k
300 k - 500 k
500 k - 1 M
0010 - 20
0020 - 40
0040 - 20 k
22 V
020 k - 50 k
050 k - 100 k
100 k - 300 k
300 k - 500 k
500 k - 1 M
0010 - 20
0020 - 40
0040 - 20 k
220 V
020 k - 50 k
050 k - 100 k
100 k - 300 k
300 k - 500 k
500 k - 1 M
0015 - 50
1100 V
0050 - 1 k
Note: 1. Stability specifications are included in Absolute Uncertainty values for the primary specifications.
1-14
Stability
1 °C [Note 1]
24 Hours
Hz
V
5
5
2
2
3
3
5
5
5
5
2
2
3
5
10
15
(ppm output + V)
150 + 20
080 + 15
012 + 2
010 + 2
010 + 2
020 + 4
100 + 10
200 + 20
150 + 20
080 + 15
012 + 4
015 + 5
015 + 5
030 + 10
070 + 20
150 + 50
150 + 20
080 + 15
012 + 8
015 + 10
015 + 10
030 + 15
070 + 100
150 + 100
150 + 200
080 + 150
012 + 80
015 + 100
015 + 100
030 + 400
100 + 10,000
200 + 20,000
(ppm output + mV)
150 + 0.5
020 + 0.5
Temperature Coefficient
10°-40 °C
0°-10 °C and
40°-50 °C
V/°C
0.05
0.05
0.05
0.05
0.05
0.05
0.1
0.1
0.2
0.2
0.3
0.3
0.4
0.4
0.5
0.5
0.2
0.3
0.2
0.3
0.2
0.3
0.4
0.5
0.5
0.5
0.6
0.6
1
1
1
1
(ppm output V)/°C
002 + 1
02 + 1
002 + 1
02 + 1
002 + 1
02 + 1
015 + 2
15 + 2
015 + 4
15 + 4
080 + 5
80 + 5
080 + 5
80 + 5
080 + 5
80 + 5
050 + 10
50 + 10
015 + 5
15 + 5
002 + 1
05 + 2
010 + 2
15 + 4
010 + 4
20 + 4
080 + 15
80 + 15
080 + 40
80 + 40
080 + 100
80 + 100
050 + 100
50 + 100
015 + 30
15 + 40
002 + 10
04 + 15
010 + 20
20 + 20
010 + 40
20 + 40
080 + 150
80 + 150
080 + 300
80 + 300
080 + 500
80 + 500
0
50 + 1000
50 + 1000
0
15 + 300
15 + 300
00
2 + 80
04 + 80
0
10 + 100
20 + 100
0
10 + 500
20 + 500
0
80 + 600
80 + 600
0
80 + 800
80 + 800
0
80 + 1000
80 + 1000
(ppm output)/°C
50
50
2
5
Maximum
Distortion
Output Impedance
Bandwidth
10 Hz-10 MHz
(% output + V)
00.05 + 10
0.035 + 10
0.035 + 10
50
0.035 + 10
0.035 + 10
000.3 + 30
000.3 + 30
000
1 + 30
00.05 + 11
0.035 + 11
0.035 + 11
50
0.035 + 11
0.035 + 11
000.3 + 30
000.3 + 30
000
1 + 30
00.05 + 16
0.035 + 16
0.035 + 16
50
0.035 + 16
0.035 + 16
000.3 + 30
000.3 + 30
000
1 + 30
Load Regulation
(ppm output+ V)
0010 + 2
00.05 + 80
0010 + 2
0.035 + 80
0010 + 4
0.035 + 80
0030 + 10
0.035 + 80
0120 + 16
0.035 + 80
0300 ppm
000.3 + 110
0600 ppm
000.3 + 110
01200 ppm
000
1 + 110
0010 + 20
00.05 + 700
0010 + 20
0.035 + 700
0010 + 30
0.035 + 700
0030 + 50
0.035 + 700
0080 + 80
0.035 + 700
0100 + 700
000.3 + 800
0200 + 1100
000.3 + 800
0600 + 3000
000
2 + 800
0010 + 200
00.05 + 10,000
0010 + 200
00.05 + 10,000
0010 + 300
00.05 + 10,000
0030 + .600
00.05 + 10,000
0080 + 3,000
000.1 + 13,000
0250 + 25,000
001.5 + 50,000
0500 + 50,000
001.5 + 50,000
1000 + 110,000
003.5 + 100,000
(% output)
0010 + 2
0010 + 1
0.15
0.07

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents