Viewing Call Quality Measurements - Fluke Network Tester User Manual

Fluke nettool inline network tester users manual
Table of Contents

Advertisement

NetTool
Users Manual

Viewing Call Quality Measurements

The VoIP Monitor tracks call quality (RTP data). To
display the VoIP Monitor, do the following:
1.
From the Main menu, select VoIP/Toolkit.
2.
On the VoIP/Toolkit menu, select VoIP Monitor to
display the screen shown in Figure 7-4:
Figure 7-4. VoIP Monitor
The VoIP Monitor includes RTP statistics and RTCP
information (when present) for both the phone side and
the network side. You can view this data this while a call is
in progress. Table 7-1 defines the RTP and RTCP
statistics seen on this screen.
7-4
Table 7-1. VoIP Monitor RTP/RTCP Statistics
Statistic
RTP frm
RTP drop
RTP jttr
RTP seqEr
ahn309s.bmp
1
RTCP
frm
1
RTCP
drop The number of dropped packets as
1
RTCP
jttr
1
RTCP is an optional control protocol that is sent from the RTP
endpoints. It contains call quality information as reported by the
two RTP endpoints involved in the conversation.
Meaning
The number of RTP frames.
The number of dropped RTP frames. An
RTP frame is considered dropped when it
does not arrive within 16 frames.
The difference between the maximum and
minimum frame inter-arrival time. This is
an unbuffered measurement of the raw
packet arrival times.
The number of frames that arrived out of
sequence but within the 16-frame-drop
window.
The number of RTP frames.
measured, post buffer, by the endpoint.
The amount of jitter as reported by the
endpoint.