Basic Manual Recording; Setting The Recording Rate And Picture Grade For Normal Recording - Mitsubishi Electric DX-TL5000E Installer Manual

Hide thumbs Also See for DX-TL5000E:
Table of Contents

Advertisement

Basic manual recording

This function is to setup the recording parameters of re-
cording setting pattern A to start recording manually. En-
sure all the cameras are connected and time and date has
been set correctly. Before you start recording, check the
repeat recording settings in the <Data Management Set-
ting for Main Memory> (System Menu Memory
Management Setting for Main Memory) first, and then make
the recording settings. (
• Make the manual recording settings on the <Set
Recording Pattern A (Normal/Timer)> (Setup
Menu Recording Set Recording Pattern A (Normal/
Timer)).
• <Set Recording Pattern A (Normal/Timer)> can be
used for manual or timer recording. <Set Recording
Pattern B (Timer)> to <Set Recording Pattern D
(Timer)> are used for timer recording only.
• Settings here are for manual recording only. For timer
recording, settings must be made on the <Timer>
menu (Setup Menu Timer). (
57.)
Setup Menu
1
Recording
Set Recording Pattern A (Normal/Timer)
1
1
Camera Check
2 + D
2 + D
2 + D
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• Basic operations
See page 82.)
See pages 56 and
Recording Setting A-Normal (Auto)
D
Recording Setting A-Normal
Recording Setting A-Normal (Easy)
D
Recording Setting A-Normal
Recording Setting A-Normal (Manual)
D
Recording Setting A-Normal
Setting the recording rate and picture grade for
normal recording
1. Execute camera check.
step
• The unit automatically detects the cameras with
video signal at their input when you select
"Execute." The detected cameras will be used in
the Auto and Easy settings calculation in step 2.
Data
• After executing the camera check, the recording
settings are made only for the camera numbers with
the video signal input when using auto or easy setting.
2. Set the normal recording menu.
step
Auto: Automatically sets the picture grade and the
recording rate by setting the recording cycle and
the recording hour per day. Set the desired settings
and then select "Execute."
• The preview screen appears automatically when
the auto setting is executed.
Easy: Sets the frame or field recording, recording
rate, and picture grade for normal recording to the
same settings for all the cameras. When the
recording rate is set to "– – –" for all the camera
numbers, normal recording does not perform. Set
the desired settings and then select "Execute."
• The preview screen appears automatically when
the easy setting is executed.
Manual: Sets per camera, the frame or field
recording, recording rate, and picture grade for
normal recording. When you set "– – –" for the
recording rate, the recording does not perform for
that camera number.
1
step
• Select "View" to display the preview screen and
check your settings.
2
step
• When you set frame recording, the recording rate
display in the preview screen turns green.
• The recording rate display in the preview screen turns
red when the value exceeds 200 pps in total.
<Estimated Recording Time>
• The estimated continuous recordable time is displayed
on the bottom of the preview screen which is dependent
on the picture grade and the recording rate settings for
normal recording. (The time does not reflect alarm
recording settings.)
• When the main device is partitioned, <Estimated
Recording Time> shows the estimated recordable time
for normal recording.
3. Press the REC/STOP button.
step
• The REC/STOP button lights up and recording
starts.
4. To stop recording, press the REC/STOP button for
step
more than 2 seconds.
• Recording stops and the light turns off.
REC/STOP
97