DIGITAL RECORDER
RS-232C COMMUNICATION CAPACITY
OPERATION MANUAL
MODEL
DX-TL308E
DX-TL304E
Contents
Disclaimer ...................................................................................................... 2
Connecting to a personal computer ........................................................... 2
Direct connection ....................................................................................................2
RS-232C connector ..................................................................................................2
RS-232C cable .........................................................................................................2
About command code table ......................................................................... 3
Cautionary note on sending commands ...................................................................3
RS-232C settings .....................................................................................................3
Command code system ...........................................................................................3
Description of command code systems ...................................................................3
Direct operation specifi cation .............................................................................3
Quasi-front panel operation command type .......................................................4
Status condition change information function .....................................................4
Command receipt confi rmation function .............................................................4
Command code table .................................................................................... 5
<Copy Menu> ...................................................................................................12
<Search Menu> ................................................................................................14
<Recording setting-Manual setting (Recording A)> ..........................................15
<Recording setting-Manual setting (Recording B)> ..........................................17
<Recording setting-Manual setting (Recording C)> ..........................................19
<Recording setting-Manual setting (Recording D)> ..........................................21
<Recording setting-EMR recording/Auto setting> ............................................23
<Recording setting-Timer program> .................................................................25
<Recording setting-Protect recorded data> ......................................................27
<HDD registration> ...........................................................................................28
<Setup> ............................................................................................................29
<Device selection> ...........................................................................................36
<Others> ...........................................................................................................37
RS-232C [Quasi-front panel operation] command form .........................................40
RS-232C Status condition change notifi cation .......................................................42
series
series

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric DX-TL308E series

  • Page 1: Table Of Contents

    DIGITAL RECORDER RS-232C COMMUNICATION CAPACITY OPERATION MANUAL MODEL DX-TL308E series DX-TL304E series Contents Disclaimer ...................... 2 Connecting to a personal computer ............2 Direct connection ....................2 RS-232C connector ....................2 RS-232C cable ......................2 About command code table ................. 3 Cautionary note on sending commands ..............3 RS-232C settings .....................3 Command code system ...................3 Description of command code systems ..............3...
  • Page 2: Disclaimer

    Check the pin layout and use the proper crossover cable for the personal computer used. This recorder RS-232C crossover cable (9 pin) * The illustration shows an example of DX-TL308E series. RS-232C connector Pin No. Letters Transmission Contents Pin No.
  • Page 3: About Command Code Table

    About command code table Cautionary note on sending commands After sending the command, make sure to check the operation of the recorder or the response such as an error before sending the next command. Some commands such as search and copy take time to respond, therefore, test the command operation suffi...
  • Page 4: Quasi-Front Panel Operation Command Type

    About command code table (continued) Quasi-front panel operation command type This system specifi es operations from a PC as if operating the actual operation panel of the recorder while viewing the output picture. Each command is corresponded to the operation button of the recorder. •...
  • Page 5: Command Code Table

    Command code table Detail of the numbers: ≤ : When “Delimiter” in the <RS-232C setting> is set to “CR,” carriage return code (0DH) is input. When “Delimiter” is set to “CR•LF,” carriage return code (0DH) and line feed code (0AH) are input. ≥...
  • Page 6 Command code table (continued) RS-232C [Direct operation specifi cation] operation setting command form (2/7) *: The commands marked with asterisk (*) are not available with DX-TL304E series. Command name Command Status Note **** ≤ Display SW,** RC≥ :Output port EX,** SW,** 00:Output A 01:Output B...
  • Page 7 Command code table (continued) RS-232C [Direct operation specifi cation] operation setting command form (3/7) Command name Command Status Note RC ≥ Start copy CP6,** :Copy destination device ≤ (Archive supported) EX,** CP6,** 02:Copy 03:Archive 10:Copy according to the calculation result of the copy range ≥...
  • Page 8 Command code table (continued) RS-232C [Direct operation specifi cation] operation setting command form (4/7) Command name Command Status Note ≤ RC ≥ Clear warning :Clearing warning display command display EX,** 0:Clear ≥ :Error type (Refer to page 4.) :System mode number (Refer to Power command) ≤...
  • Page 9 Command code table (continued) RS-232C [Direct operation specifi cation] operation setting command form (5/7) *: The commands marked with asterisk (*) are not available with DX-TL304E series. Command name Command Status Note RC ≥ Execute data lock DLOKS,** :Device area including the data to be locked ≤...
  • Page 10 :Time to be searched/minute (00-59) :Time to be searched/second (00-59) :Error type (Refer to page 4.) :Playback mode number (Refer to Playback command) (10) <For DX-TL308E series> 00-07: Camera 1-8 20: All cameras <For DX-TL304E series> 00-03: Camera 1-4 20: All cameras ≤...
  • Page 11 Command code table (continued) RS-232C [Direct operation specifi cation] operation setting command form (7/7) Command name Command Status Note ≤ RC ≥ Bookmark search PB21,** :Output port of playback picture EX,** PB21,** 00:Output A ≥ :Bookmark number to be searched 00:1 01:2 02:3...
  • Page 12: Rs-232C [Direct Operation Specifi Cation] Menu Setting Command Form

    Command code table (continued) RS-232C [Direct operation specifi cation] menu setting command form <Copy Menu> (1/3) *: The commands marked with asterisk (*) are not available with DX-TL304E series. Menu Menu item Command Status Note ***** Set the copy Copy from <Menu setting>...
  • Page 13 Command code table (continued) RS-232C [Direct operation specifi cation] menu setting command form <Copy Menu> (2/3) Menu Menu item Command Status Note ***** Set the start Start point/year <Menu setting> <Writing of menu information> :01070 RC ≥EX,** ***** point and DW,***** DW,*** :00001-00037 (year 2001-2037)
  • Page 14: Search Menu

    Command code table (continued) RS-232C [Direct operation specifi cation] menu setting command form <Copy Menu> (3/3) *: The commands marked with asterisk (*) are not available with DX-TL304E series. Menu Menu item Command Status Note ***** Defi ne the Start <Menu setting>...
  • Page 15: Recording Setting-Manual Setting (Recording A)

    Command code table (continued) RS-232C [Direct operation specifi cation] menu setting command form <Recording setting-Manual setting (Recording A)> (1/2) *: The commands marked with asterisk (*) are not available with DX-TL304E series. Menu Menu item Command Status Note ***** Picture size Picture size <Menu setting>...
  • Page 16 ***** Output 1/CAM 02431:Sensor 1 02441:Sensor 2 02451:Sensor 3 02461:Sensor 4 02471:Sensor 5* 02481:Sensor 6* 02491:Sensor 7* 02501:Sensor 8* ***** <For DX-TL308E series> 00000-00007:1-8, 65535:- <For DX-TL304E series> 00000-00003:1-4, 65535:- :Error type (Refer to page 4.) ÷ ÷ ***** Output 1/P.set...
  • Page 17: Recording Setting-Manual Setting (Recording B)

    Command code table (continued) RS-232C [Direct operation specifi cation] menu setting command form <Recording setting-Manual setting (Recording B)> (1/2) *: The commands marked with asterisk (*) are not available with DX-TL304E series. Menu Menu item Command Status Note ***** Picture size Picture size <Menu setting>...
  • Page 18 ***** Output 1/CAM 03431:Sensor 1 03441:Sensor 2 03451:Sensor 3 03461:Sensor 4 03471:Sensor 5* 03481:Sensor 6* 03491:Sensor 7* 03501:Sensor 8* ***** <For DX-TL308E series> 00000-00007:1-8, 65535:- <For DX-TL304E series> 00000-00003:1-4, 65535:- :Error type (Refer to page 4.) ÷ ÷ ***** Output 1/P.set...
  • Page 19: Recording Setting-Manual Setting (Recording C)

    Command code table (continued) RS-232C [Direct operation specifi cation] menu setting command form <Recording setting-Manual setting (Recording C)> (1/2) *: The commands marked with asterisk (*) are not available with DX-TL304E series. Menu Menu item Command Status Note ***** Picture size Picture size <Menu setting>...
  • Page 20 ***** Output 1/CAM 04431:Sensor 1 04441:Sensor 2 04451:Sensor 3 04461:Sensor 4 04471:Sensor 5* 04481:Sensor 6* 04491:Sensor 7* 04501:Sensor 8* ***** <For DX-TL308E series> 00000-00007:1-8, 65535:- <For DX-TL304E series> 00000-00003:1-4, 65535:- :Error type (Refer to page 4.) ÷ ÷ ***** Output 1/P.set...
  • Page 21: Recording Setting-Manual Setting (Recording D)

    Command code table (continued) RS-232C [Direct operation specifi cation] menu setting command form <Recording setting-Manual setting (Recording D)> (1/2) *: The commands marked with asterisk (*) are not available with DX-TL304E series. Menu Menu item Command Status Note ***** Picture size Picture size <Menu setting>...
  • Page 22 ***** Output 1/CAM 05431:Sensor 1 05441:Sensor 2 05451:Sensor 3 05461:Sensor 4 05471:Sensor 5* 05481:Sensor 6* 05491:Sensor 7* 05501:Sensor 8* ***** <For DX-TL308E series> 00000-00007:1-8, 65535:- <For DX-TL304E series> 00000-00003:1-4, 65535:- :Error type (Refer to page 4.) ÷ ÷ ***** Output 1/P.set...
  • Page 23: Recording Setting-Emr Recording/Auto Setting

    Command code table (continued) RS-232C [Direct operation specifi cation] menu setting command form <Recording setting-EMR recording/Auto setting> *: The commands marked with asterisk (*) are not available with DX-TL304E series. Menu Menu item Command Status Note ***** EMR recording Picture size <Menu setting>...
  • Page 24: Recording Setting-Motion Detection Setting/Audio Recording Settings

    Command code table (continued) RS-232C [Direct operation specifi cation] menu setting command form <Recording setting-Motion detection setting/Audio recording settings> *: The commands marked with asterisk (*) are not available with DX-TL304E series. Menu Menu item Command Status Note ***** Motion Sensitivity <Menu setting>...
  • Page 25: Recording Setting-Timer Program

    Command code table (continued) RS-232C [Direct operation specifi cation] menu setting command form <Recording setting-Timer program> (1/2) Menu Menu item Command Status Note ***** Timer program Day <Menu setting> <Writing of menu information> DW,***** RC≥EX,** DW,*** 09000:Line 1 09010:Line 2 09020:Line 3 ***** ≤...
  • Page 26 Command code table (continued) RS-232C [Direct operation specifi cation] menu setting command form <Recording setting-Timer program> (2/2) Menu Menu item Command Status Note ***** Holiday and Holiday setting <Menu setting> <Writing of menu information> special day DW,***** RC≥EX,** DW,*** 09160:Month 09161:Day (Holiday 1) *****...
  • Page 27: Recording Setting-Protect Recorded Data

    Command code table (continued) RS-232C [Direct operation specifi cation] menu setting command form <Recording setting-Protect recorded data> Menu Menu item Command Status Note ***** Protect Start point/year <Menu setting> <Writing of menu information> :06080 RC ≥EX,** ***** recorded data DW,***** DW,*** :00001-00037 (year 2001-2037) *****...
  • Page 28: Hdd Registration

    Command code table (continued) RS-232C [Direct operation specifi cation] menu setting command form <HDD registration> Menu Menu item Command Status Note ***** HDD sleep HDD sleep mode <Menu setting> <Writing of menu information> :06970 ***** mode DW,***** RC≥EX,** DW,*** ***** ≤...
  • Page 29: Setup

    Command code table (continued) RS-232C [Direct operation specifi cation] menu setting command form <Setup> (1/7) Menu Menu item Command Status Note ***** Clock and Clock setting/ <Menu setting> <Writing of menu information> :10001 RC ≥EX,** ***** language year DW,***** DW,*** :00001-00037 (year 2001-2037) ***** ≤...
  • Page 30 Command code table (continued) RS-232C [Direct operation specifi cation] menu setting command form <Setup> (2/7) Menu Menu item Command Status Note ***** Warning Remain <Menu setting> <Writing of menu information> display • DW,***** RC≥EX,** DW,*** 10032:Normal 10037:Alarm ***** ≤ ***** ≥...
  • Page 31 Command code table (continued) RS-232C [Direct operation specifi cation] menu setting command form <Setup> (3/7) *: The commands marked with asterisk (*) are not available with DX-TL304E series. Menu Menu item Command Status Note ***** Mode-out• Trigger <Menu setting> <Writing of menu information> Remaining DW,***** RC≥EX,**...
  • Page 32 Command code table (continued) RS-232C [Direct operation specifi cation] menu setting command form <Setup> (4/7) *: The commands marked with asterisk (*) are not available with DX-TL304E series. Menu Menu item Command Status Note Output A <Menu setting> <Writing of menu information> DX-TL308E:<Split 4a>...
  • Page 33 Command code table (continued) RS-232C [Direct operation specifi cation] menu setting command form <Setup> (5/7) *: The commands marked with asterisk (*) are not available with DX-TL304E series. Menu Menu item Command Status Note Output B <Menu setting> <Writing of menu information> DX-TL308E:<Split 4a>...
  • Page 34 Command code table (continued) RS-232C [Direct operation specifi cation] menu setting command form <Setup> (6/7) *: The commands marked with asterisk (*) are not available with DX-TL304E series. Menu Menu item Command Status Note ***** Alarm display Alarm display <Menu setting> <Writing of menu information>...
  • Page 35 Command code table (continued) RS-232C [Direct operation specifi cation] menu setting command form <Setup> (7/7) *: The commands marked with asterisk (*) are not available with DX-TL304E series. When changing “Transmission rate” in <RS-232C setting> via RS-232C command, the actual operation may not refl...
  • Page 36: Device Selection

    Command code table (continued) RS-232C [Direct operation specifi cation] menu setting command form <Device selection> Menu Menu item Command Status Note ***** Change audio Play device <Menu setting> <Writing of menu information> :00000 ***** and play selection DW,***** RC≥EX,** DW,*** ***** ≤...
  • Page 37: Others

    Command code table (continued) RS-232C [Direct operation specifi cation] menu setting command form <Others> *: The commands marked with asterisk (*) are not available with DX-TL304E series. Menu Command Status Note ≤ RC ≥ Registering BKMS,** :Bookmark number ≥ bookmark EX,** BKMS,** 00:1...
  • Page 38: Rs-232C [Direct Operation Specifi Cation] Status Check Command Form

    Command code table (continued) RS-232C [Direct operation specifi cation] status check command form (1/2) *: The commands marked with asterisk (*) are not available with DX-TL304E series. Command Status Note RC ≥ <Inquiry for setting :System status (41) recorder status> EX,** MD,** 00:Power off...
  • Page 39 Command code table (continued) RS-232C [Direct operation specifi cation] status check command form (2/2) *: The commands marked with asterisk (*) are not available with DX-TL304E series. Command Status Note RC ≥ <Inquiry for :Display output port display status> EX,** SWQ,** 00:Output A 01:Output B...
  • Page 40: Rs-232C [Quasi-Front Panel Operation] Command Form

    Command code table (continued) RS-232C [Quasi-front panel operation] command form *: The commands marked with asterisk (*) are not available with DX-TL304E series. Button Command Status Note KKP0 ≤ RC ≥ POWER Power On/Off KKP0 ≥ EX,** :Error type (Refer to page 4.) KKR0 ≤...
  • Page 41 Command code table (continued) RS-232C Status condition change notifi cation (1/2) *: The commands marked with asterisk (*) are not available with DX-TL304E series. Mode Status Note **** Warning LOG6K,**** :Log number notifi cation 1100:Recording/Full (Normal area) 1101:Recording/Full (Alarm area) 1102:Recording/Full (Emergency area) ************ 1200:Recording/Remaining capacity warning (Normal area)
  • Page 42: Rs-232C Status Condition Change Notifi Cation

    03:Signal detected (during recording) n=The number of cameras without :The number of cameras without signal/with signal signal/with signal. <For DX-TL308E series> 01-08 <For DX-TL304E series> 01-04 (3)-(n+2) :Camera number of which signal is detected/is not detected (n=The number of cameras without signal/with signal.)
  • Page 43 SLD Security & Communications The Old Forge, Ockham Lane, Ockham, Surrey GU236PH England Phone +44.1483225633 · Fax +44.1483225634 sales@sld.co.uk · www.sld.co.uk...