Raid Card - Lenovo ThinkServer RD630 Hardware Maintenance Manual

Machine types: 2577, 2579, 2592, 2593, 2594, and 2595
Hide thumbs Also See for ThinkServer RD630:
Table of Contents

Advertisement

Figure 20. 2.5-inch hot-swap hard disk drive status LEDs
1
Hard disk drive activity LED
Off
On, green
Blinking, green
On, green
On, green
Blinking, green

RAID card

This topic provides information to help you locate the connectors on the RAID card installed in the upper slot
of the riser card assembly 1.
Your server comes with a RAID card to provide advanced SATA/SAS hardware RAID functions. You also
can purchase a supported RAID card from Lenovo and install it into the server. See "Replacing the RAID
card" on page 142.
Notes:
• The option kit for the RAID card is designed for different types of servers and might contain additional
cables that are not required for your server.
• The server must have a RAID card and an expander card installed to support more than eight hard
disk drives.
2
Hard disk drive RAID status LED
Off
Off
Off
Blinking rapidly (about four flashes
per second), amber
On, amber
Blinking slowly (about one flash per
second), amber
Description
The hard disk drive has failed or is
not present.
The hard disk drive is present but not
in use.
The hard disk drive is active and data
is being transferred.
The RAID controller is identifying the
hard disk drive.
The RAID array has failed and cannot
be recovered. You need to recreate a
new array.
The hard disk drive is being rebuilt.
.
Chapter 3
Product overview
33

Advertisement

Table of Contents
loading

Table of Contents