Runco PLASMAWALL XP-65DHD Owner's Operating Manual page 57

High definition, 1080p flat panel plasma display with widevision
Hide thumbs Also See for PLASMAWALL XP-65DHD:
Table of Contents

Advertisement

Table 5-1. Troubleshooting Chart (continued)
Symptom
Colors in the image are
swapped; for example, reds
appear blue or vice versa.
RGB-HD images appear
"noisy."
Computer images do not dis-
play correctly.
The image is too large or too
small.
PlasmaWall XP-65DHD Owner's Operating Manual
Possible Cause(s)
• The Red/Pr, Green/Y or
Blue/Pb outputs from the
source are connected to
the wrong inputs on the
DHD Controller.
• The Red, Green or Blue
(analog) outputs from the
DHD Controller are
connected to the wrong
inputs on the PlasmaWall.
• Clock and Phase settings
need adjustment.
• The resolution and
frequency of the video
card in the computer are
not compatible with the
PlasmaWall.
• Image size needs
adjusting.
Solution
• Ensure that the source
outputs are connected to
the correct DHD Controller
input.
• Ensure that the DHD
Controller outputs are
connected to the correct
inputs on the PlasmaWall.
• Adjust Clock and Phase
settings (refer to ISF Night
- Input Color on
page 39).
• Select a compatible
resolution and vertical
frequency (refer to
PlasmaWall
Specifications on
page 55).
• Adjust the image size (refer
to Input Position on
page 36 or Display
Device - Display
Position on page 42).
47