Operation

Service

Service
Test Video
Input Names
Remote Control
Analog Out Mode
Display Device
HD Format
Triggers
Miscellaneous
System Reset
Restore Saved Settings
Input Names
Restore
Composite
Composite
S-Video 1
S-Video 1
S-Video 2
S-Video 2
Component SD Component SD
HD/RGB 1
HD/RGB 1
HD/RGB 2
HD/RGB 2
HDMI 1
HDMI 1
HDMI 2
HDMI 2
Save
• Runco/ISF Logo Splash Screen Timers: When you turn on the PlasmaWall, it
projects a welcome screen with the Runco logo followed by one with the ISF logo.
Select Splash Timer from the Splash Configure menu to set the amount of time that
these two images appear. The range is from 2 to 60 seconds, in one-second
increments.
Use the up or down cursor button to select a timer value to adjust. Use the right or left
cursor button to change the timer value. Press MENU when you have finished
configuring both timers.
OSD Position: Select OSD Position, press ENTER and use the arrow buttons to change
the size and position of the OSD controls.
Use the Service menu to access advanced display configuration settings. This menu
should be used by ISF-certified technicians only.
Note
Test Video: Select Test Video from the Service Menu to access the internal test patterns
on the PlasmaWall. Four patterns are available, consisting of white/gray or colored bars.
These are useful for calibrating other theater source components (DVD player, HD tuner
etc.) that have their own picture controls.
Press MENU to exit test pattern mode.
Input Names: You can give each DHD Controller input a descriptive name. For example,
you may want to change the default input name to the type of source component
connected to it: "VCR," "DVD," "Laptop" et cetera. Composite, S-Video and Component
SD input names can be up to 12 characters long; the others can be up to eight characters
long.
To edit an input name, select Input Names from the Service menu. Press
an input and press ENTER. Use the
to select a character to change. When you have finished editing the input name, press
MENU.
To restore the default input name, press
"Restore" column. Then, press ENTER.
To save input names so that they can be restored after a System Reset (described on
page 44), press
Note
You must enter a passcode to access the Service menu.
or
repeatedly to highlight "Save." Then, press ENTER.
The
button takes you from top to bottom in the left column, then
from top to bottom in the right column. To highlight "Save," scroll
through both columns.
40
buttons to change a character; press
repeatedly to highlight that input name in the
PlasmaWall XP-65DHD Owner's Operating Manual
or
to select
or

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plasmawall xp-65dhdxa

Table of Contents