Type Tests

7.2 IEEE 1613 Type Tests

IEEE
IEEE Test
1613
Clause
C37.90.3
9
C37.90.2
8
C37.90.1
7
C37.90.1
7
C37.90
6
C37.90
6

Table 25 - IEEE 1613 Type Tests

Notes:
If the unit contains copper ports, the IEEE 1613 conformance is Class 1 (During
disturbance, errors may occur but recovery is automatic).
If the unit contains all fiber ports, the IEEE 1613 conformance is Class 2 (During
disturbance, no errors will occur).

7.3 IEC Environmental Type Tests

Test
IEC 60068-2-1
IEC 60068-2-2
Humidity (Damp
IEC 60068-2-30
IEC 60255-21-1
IEC 60255-21-2

Table 26 - Environmental Type Tests

®
RuggedCom
Description
Enclosure Contact
ESD
Enclosure Air
Radiated RFI
Enclosure ports
Signal ports
D.C. Power ports
Fast Transient
A.C. Power ports
Earth ground ports
Signal ports
Oscillatory
D.C. Power ports
A.C. Power ports
Signal ports
H.V. Impulse
D.C. Power ports
A.C. Power ports
Signal ports
Dielectric
D.C. Power ports
Strength
A.C. Power ports
Description
Cold
Test Ad
Temperature
Dry Heat
Test Bd
Test Db
Heat, Cyclic)
Vibration
Shock
42
RuggedServer™ RS416 Family Installation Guide rev118
+/- 4kV @ 2.5kHz
2.5kV common mode @ 1MHz
2.5kV common & differential mode @ 1MHz
2.5kV common & differential mode @ 1MHz
5 kV (Failsafe Relay)
Test Levels
-40 deg. C, 16 Hours
+85 deg. C, 16 Hours
95% (non-condensing), 55°C, 6
cycles
2g @ (10-150) Hz
30g @ 11 ms
Test Levels
+/- 8kV
+/- 15kV
35 V/m
+/- 4kV
+/- 4kV
+/- 4kV
5 kV
5 kV
2kVAC
1.5kVDC
2kVAC
Severity
Levels
N/A
N/A
N/A
Class 2
Class 2

Advertisement