SERVICE MANUAL
23JUL01
SLIDE LIFT LEVER MANUAL
SM5766-1
Page
43 of 96
Warning
Dangerous Voltage
1
Disconnect the main power.
2
Do the removal for the MECHANISM ASSEMBLY.
3
Place the MECHANISM ASSEMBLY on the MECHANISM RUNNING FIXTURE.
4
Press and hold the SELECT LEVER down to move the SLIDE LIFT LEVER to the
highest position.
5
Measure the height of the SLIDE LIFT LEVER. Use SLIDE LIFT LEVER GAUGE TL-
3001. The SLIDE LIFT LEVER should make contact with the low surface of the SLIDE
LIFT LEVER GAUGE TL-3001; the SLIDE LIFT LEVER should not make contact with the
high surface of the SLIDE LIFT LEVER GAUGE TL-3001.
6
Bend the SLIDE LIFT LEVER until the adjustment is correct.
SLIDE LIFT
LEVER GUAGE
TL-3001
Adjustments
SLIDE LIFT
LEVER
SELECT
LEVER
(not shown)
A091_0016BCA