Removal For The Lamp Module Receptacle - Kodak Ektalite 500 Service Manual

Hide thumbs Also See for Ektalite 500:
Table of Contents

Advertisement

SERVICE MANUAL
23JUL01

Removal for the LAMP MODULE RECEPTACLE

SM5766-1
Page
17 of 96
Warning
Dangerous Voltage
1
Disconnect the main power.
2
Do the removal for the LOWER HOUSING ASSEMBLY.
3
Disconnect the 3 CONNECTORS on the MAIN BOARD. It is not necessary to disconnect
the CONNECTORS next to the LOWER LIGHT BAFFLE ASSEMBLY.
4
Lift the MAIN BOARD up.
5
Cut and remove the necessary WIRE TIES.
6
Disconnect the blue wire from P102 and the white wire from P10 on the MAIN BOARD.
7
Remove the 2 Torx SCREWS on the left side of the LOWER LIGHT BAFFLE
ASSEMBLY.
8
Loosen the Torx SCREW on the right side of the LOWER LIGHT BAFFLE ASSEMBLY
approximately 1/2 way.
9
Lift and remove the LOWER LIGHT BAFFLE ASSEMBLY.
10
Lift the GRILL ASSEMBLY up.
11
Remove the 2 long Torx SCREWS from the BLOWER COVER ASSEMBLY.
12
Lift the BLOWER COVER ASSEMBLY up.
13
Lift and move the PREHEAT DUCT up.