Removal for the THERMAL FUSE ASSEMBLY

Warning
Dangerous Voltage
1
Disconnect the main power.
2
Do the removal for the LOWER HOUSING ASSEMBLY.
3
Disconnect the 3 CONNECTORS on the MAIN BOARD. It is not necessary to disconnect
the CONNECTOR next to the LOWER LIGHT BAFFLE ASSEMBLY.
4
Lift the MAIN BOARD up.
5
Cut and remove the necessary WIRE TIES.
6
Remove the brown wire from the THERMAL FUSE ASSEMBLY on the POWER SWITCH.
7
Remove the brown wire from the INTERLOCK SWITCH on the LOWER LIGHT BAFFLE.
8
Loosen the Torx SCREW on the PREHEAT DUCT approximately half way.