SERVICE MANUAL

Replacing the THERMAL FUSE ASSEMBLY

Warning
Dangerous Voltage
[1] Disconnect the main power.
[2] Do the replacement procedure for the LOWER HOUSING ASSEMBLY.
[3] Cut and remove the necessary WIRE TIES.
[4] Remove the black wire from the THERMAL FUSE ASSEMBLY on the POWER SWITCH.
[5] Remove the gray wire from the THERMAL FUSE ASSEMBLY from the POWER CORD.
[6] Loosen the Torx SCREW on the PREHEAT DUCT approximately half way.
[7] Pull the THERMAL FUSE ASSEMBLY out of hole of the LOWER LIGHT BAFFLE ASSEMBLY.

Installing the THERMAL FUSE ASSEMBLY

[1] Do the replacement procedure for the THERMAL FUSE ASSEMBLY in reverse order.

Replacing the LAMP MODULE RECEPTACLE

Warning
Dangerous Voltage
[1] Disconnect the main power.
[2] Do the replacement procedure for the LOWER HOUSING ASSEMBLY.
[3] Cut and remove the necessary WIRE TIES.
[4] Remove the 2 Torx SCREWS on the left side of the LOWER LIGHT BAFFLE ASSEMBLY.
[5] Loosen the Torx SCREW on the right side of the LOWER LIGHT BAFFLE ASSEMBLY approximately 1/2 way.
10
A100_0015GCA
POWER SWITCH
A100_0015GA
SCREW
PRE-HEAT DUCT
THERMAL FUSE
18NOV97 – SM5440-1

Hide quick links: