JVC KM-H2500 Manual page 52

Hide thumbs Also See for KM-H2500:
Table of Contents

Advertisement

6.
Use the Triggr knob to select when the GPI
output is triggered. You can choose from the
following:
• Off — The GPI output is not triggered.
• Start — The GPI output is triggered at the
start of EDL data capture.
• Stop — The GPI output is triggered at the end
of EDL data capture.
• Both — The GPI output is triggered at both
the start and end of EDL data capture.
7.
If you selected Start or Both in step 6, use the
PreDly knob to specify the number of frames the
switcher delays after the GPI output is triggered
before EDL capture begins.
Note:
• If no GPI banks are configured as outputs, you can
not select s GPI output in step 5 above.
• If the selected GPI output is configured as a level
trigger, it remains in the latched state until you
unlatch it.
For More Information on...
• configuring GPI banks, refer to the section
"General Purpose Interface (GPI)" on page 48.
To apply an offset to LTC timecode data:
2
1
3,5
1.
Press MENU.
2.
Press the SYSTEM Wipe Pattern button.
3.
Press NEXT until LivEDL Config is displayed.
4.
Press the LiveEDL Config knob to display the
EDL Configuration menu.
5.
Press NEXT until LTCOff is displayed.
6.
Use the LTCOff knob to select an offset (in
frames) to apply to the LTC timecode.
Note:
• LTC offsets are only available if you are using a
Ross Video GearLite TSC-9902 LTC to Serial
Converter.
For More Information on...
• configuring a Ross Video GearLite TSC-9902 LTC
to Serial Converter, refer to the section "Editor
Control" on page 19.
46
4
6
Capturing EDL Data
Capturing EDL data is manually started and stopped.
You can retrieve EDL files via an FTP connection or
by saving them to a USB drive. You can delete EDL
files from the switcher to free space for more data
capture.
It is strongly recommended that you use a Ross
Video GearLite TSC-9902 LTC to Serial Converter to
provide timecode information when capturing EDL
data.
To start capturing an EDL file:
1
2
1.
Press MENU.
2.
Press the USER Wipe Pattern button.
3.
Press the LiveEDL knob to display the LiveEDL
menu.
4.
Use the left knob to select the EDL file you wish
to capture to.
5.
Press the Start knob.
Note:
• A maximum of 999 EDL files may be present on
the switcher.
For More Information on...
• configuring a Ross Video GearLite TSC-9902 LTC
to Serial Converter, refer to the section "Editor
Control" on page 19.
To stop capturing an EDL file:
1
2
1.
Press MENU.
2.
Press the USER Wipe Pattern button.
3.
Press the LiveEDL knob to display the LiveEDL
menu.
4.
Press the Stop knob.
3
3
4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Km-h3000

Table of Contents