Configuring The Mac Address-Table Move Update Feature - Cisco Catalyst 3120 Software Manual

Catalyst blade switch for hp
Hide thumbs Also See for Catalyst 3120:
Table of Contents

Advertisement

Chapter 20
Configuring Flex Links and the MAC Address-Table Move Update Feature
When a Flex Link interface comes up, VLANs preferred on this interface are blocked on the peer
interface and moved to the forwarding state on the interface that has just come up. In this example, if
interface Gi2/0/6 comes up, VLANs preferred on this interface are blocked on the peer interface Gi2/0/8
and forwarded on Gi2/0/6.
Switch# show interfaces switchport backup
Switch Backup Interface Pairs:
Active Interface
------------------------------------------------------------------------
GigabitEthernet2/0/6
Vlans Preferred on Active Interface: 1-50
Vlans Preferred on Backup Interface: 60, 100-120
Switch# show interfaces switchport backup detail
Switch Backup Interface Pairs:
Active Interface
------------------------------------------------------------------------
FastEthernet1/0/3
Vlans Preferred on Active Interface: 1-2,5-4094
Vlans Preferred on Backup Interface: 3-4
Preemption Mode
Bandwidth : 10000 Kbit (Fa1/0/3), 100000 Kbit (Fa1/0/4)
Mac Address Move Update Vlan : auto

Configuring the MAC Address-Table Move Update Feature

This section contains this information:
Beginning in privileged EXEC mode, follow these steps to configure an access switch to send MAC
address-table move updates:
Command
Step 1
configure terminal
Step 2
interface interface-id
Step 3
switchport backup interface interface-id
or
switchport backup interface interface-id mmu
primary vlan vlan-id
OL-12247-01
Backup Interface
GigabitEthernet2/0/8
Backup Interface
FastEthernet1/0/4
: off
Configuring a switch to send MAC address-table move updates
Configuring a switch to get MAC address-table move updates
Configuring Flex Links and MAC Address-Table Move Update
State
Active Up/Backup Standby
State
Active Down/Backup Up
Purpose
Enter global configuration mode.
Specify the interface, and enter interface configuration
mode. The interface can be a physical Layer 2 interface or
a port channel (logical interface). The port-channel range
is 1 to 48.
Configure a physical Layer 2 interface (or port channel),
as part of a Flex Link pair with the interface. The MAC
address-table move update VLAN is the lowest VLAN ID
on the interface.
Configure a physical Layer 2 interface (or port channel)
and specify the VLAN ID on the interface, which is used
for sending the MAC address-table move update.
When one link is forwarding traffic, the other interface is
in standby mode.
Cisco Catalyst Blade Switch 3120 for HP Software Configuration Guide
20-9

Advertisement

Table of Contents
loading

Table of Contents