Check LEDs

See
Figure 6
10.
Figure 6 Verifying power-on LEDs
.
Table 10 Power-on LEDs
Item
1
2
3
4

Set the switch Ethernet IP address

To set the Ethernet IP address:
1.
Verify that the enclosure is powered on.
2.
Verify that the switch is installed.
3.
Choose one of the following methods to set the Ethernet IP address:

Using Enclosure Bay IP Addressing (EBIPA)

Using external DHCP
Setting the IP address manually
Using Enclosure Bay IP Addressing (EBIPA)
To set the Ethernet IP address using EBIPA:
1.
Open a web browser and connect to the active OA.
2.
Enable EBIPA for the corresponding interconnect bay.
3.
Click Apply to restart the switch.
4.
Verify the IP address using a Telnet or SSH login to the switch, or by selecting the switch in the
OA GUI Rack Overview window.
to locate power-on LEDs. Verify that the LEDs match the indicators described in
Description
UID LED
Health ID LED
Module status LED
Port status LED
Indicators
Off
Steady green light
Steady green light
Steady green light