CAUTION
Staples whic
to stop wor
When using the insulated
staples,
ou fasten them only as tightly
Make wire attachments at STB
Splitting and stripping wire ends to be
connected as shown (Fig. 3-6) .
Loosen terminal screws.
Insert wire under flat plate and tighten screw. It
does not matter which wire, white or striped,
goes on which terminal (Fig. 3-7) .
Make wire attachments at power head.
oMax . STB
#2 and #3 on power head (Fig. 3-8) .
. STB
terminals #3 and #4 on power head (Fig. 3-8) .
4. Check the following .
Insure that no part of door or its hardware is in
path between lenses of source and sensor .
Insure that tops of lenses are between 5
above the floor (Fig. 3-9) . The brackets are
flexible and can be adjusted slightly if needed.
NOTE: STB alignment check must be performed
following connection to electrical power (see page 21).
DO NOT PLUG IN YET!
Safe-T-Beam
®
Alignment Check
After turning the electrical power on, if the
STB's are not in proper alignment, the red
LED (Source) will blink continuously.
To correct the problem – the brackets are
flexible and can be adjusted slightly to bring
the system into alignment.
When the STB's are in alignment the red LED
will stop blinking and stay on.
STB
SELF-DIAGNOSTIC TROUBLESHOOTING
SOURCE ( RED LED ) SENSOR ( GREEN LED ) INDICATED CONDITION
ON
ON
OFF
OFF
ON
OFF
2 BLINKS, PAUSE (REPEAT)
ON
2 BLINKS, PAUSE (REPEAT)
OFF
ON
3 BLINKS, PAUSE (REPEAT)
4 BLINKS, PAUSE (REPEAT)
ON
NOTE : IF OPERATING PROBLEM EXISTS, THE DOOR CAN BE CLOSED IF YOU: 1 . DISCONNECT THE STB SYSTEM FROM THE OPERATOR AND 2 . HOLD WALL CONTROL BUTTON
DOWN UNTIL DOOR IS CLOSED. ( REMOTE CONTROL & WIRELESS KEYPAD WILL NOT WORK WITHOUT STB )
CU S S TOM M E E R SER R VI I C C E E : : 1. . 80 0 0.354 4 .3 3 643 3 or w w ww.g g e e n n i i ec c om m pa a ny y .c c om
ugly.
s.
'
s are connected to terminals
'
s are connected to
'
-6
"
"
NORMAL OPERATION
1.POWER HEAD NOT POWERED
2.WIRING FROM POWER HEAD BAD
1.WIRING TO SOURCE MISSING OR BAD
2.POWER HAS BEEN INTERRUPTED
1.BEAM NOT ALIGNED 2. BEAM OBSTRUCTED
3.SENSOR DEFECTIVE
1.WIRE TO SENSOR MISSING OR BAD
2.SENSOR DEFECTIVE
1.SENSOR RECEIVING INTERFERENCE
1.SOURCE NOT SENDING PULSES
2.SOURCE DEFECTIVE
FIG. 3-6
FIG. 3-7
Splitting and
Attachments
at STB.
top edge of lens between
3
4
FIG. 3-8 (Stealth)
Attachments at
po
.
FIG. 3-9 Check lens height .
REQUIRED ACTION
NONE REQUIRED
1.CHECK BREAKERS, FUSES, PLUGS
2.CHECK WIRING FOR OBVIOUS SHORTS
1.CHECK WIRING
2.REMOVE POWER AND REAPPLY
1.CHECK ALIGNMENT 2. CHECK FOR OBSTRUCTION
3.CALL CUSTOMER SERVICE
1.CHECK WIRING
2.CALL CUSTOMER SERVICE
1.ATTEMPT TO DETERMINE SOURCE OF INTERFERENCE
2.CALL CUSTOMER SERVICE
1.CALL CUSTOMER SERVICE
2.CALL CUSTOMER SERVICE
2
3
FIG. 3-8 (ProMax)
Attachments at
po
.
5
- 6
above floor.
"
"