Clearances To Combustibles - Quadra-Fire CB1200M-MBK Owner's Manual

Classic bay 1200 pellet stove
Hide thumbs Also See for CB1200M-MBK:
Table of Contents

Advertisement

R
B. Clearances to Combustibles (UL and ULC)
A
B
Straight Back Against
Wall
A
Back Wall to Appliance
B
Side Wall to Appliance
Corner Installation
C
Walls to Appliance
Installations with:
3 to 3 inch Top Vent Adapter and
3 to 6 inch Offset Adapter Kit
D
F
E
Vertical Installation
D
Back Wall to Flue Pipe
E
Side Wall to Top
F
Back Wall to Appliance
Corner Installation
G
Walls to Appliance
December 16, 2011
C
C
Inches
Millimeters
2
51
6
152
Inches
Millimeters
2
51
G
G
Inches
Millimeters
3
76
6
152
7.5
191
Inches
Millimeters
2
51
7014-179D
Alcove Installation
Minimum Alcove Height
Minimum Alcove Width
Maximum Alcove Depth
Minimum Alcove Side Wall
Top of Unit to Combustibles
WARNING
Fire Risk.
Comply with all minimum clearances to
combustibles as specified.
Failure to comply may cause house fire.
NOTE:
• Illustrations reflect typical installations and are FOR
DESIGN PURPOSES ONLY.
• Illustrations/diagrams are not drawn to scale.
• Actual installation may vary due to individual design
preference.
CB 1200 Pellet Stove
Inches
Millimeters
44
1117
40-1/2
1029
36
915
6
152
12-1/2
318
Page 9

Advertisement

Table of Contents
loading

Table of Contents