Through The Wall - Quadra-Fire CB1200M-MBK Owner's Manual

Classic bay 1200 pellet stove
Hide thumbs Also See for CB1200M-MBK:
Table of Contents

Advertisement

CB 1200 Pellet Stove
B. Through The Wall
Horizontal termination cap must be a minimum of 12 inches.
(305mm) from the wall. Approved for mobile home instal-
lations. Must use 3 or 4 inch (76-102mm) "L" or "PL" listed
pellet venting or listed double wall pipe and a Quadra-Fire
outside air kit in mobile homes.
NOTICE:
Please note that while the minimum
clearance for the termination cap is 6
inches (152mm) there is the possibly
of soot buildup around the termina-
tion area. If this occurs we suggest
to move the termination further away
from the house to prevent it.
Page 14
Straight Out
6 in.
(152mm)
Minimum
From Glass
Figure 14.1
45 Degree
Illustration shows venting going in both directions.
Choose which one is best for your installation.
Wall
Thimble
6 in.
(152mm)
Minimum
Figure 14.2
7014-179D
NOTE:
In Canada, where passage through a wall or partition of
combustible construction is desired, the installation shall
conform to CAN/CSA-B365
2 in.
(51mm)
Minimum
Non-combustible Hearth Pad
6 in. (152mm)
Minimum
2 in. (51mm)
Minimum
R
Horizontal
W all
T ermination
Thimble
Cap
6 in.
(152mm)
Minimum
2 in. (51mm)
Minimum
December 16, 2011

Advertisement

Table of Contents
loading

Table of Contents