TROU B LES H OOTi NG
Probmem
No AC output
is avaHabme, but
generator
is running.
Generator
runs
good
at no=moad
but
"bogs"
down"
when
loads
are
connected.
Generator
will
not
start;
or
starts
and runs rough.
Cause
I.
One
of the circuit
breakers
is
open.
Z
Fault in generator.
3.
Poor connection
or defective
cord
set.
4.
Connected
device
is bad.
[.
Short
circuit
in a connected
load.
Z
Generator
is overloaded.
3.
Shorted
generator
circuit.
I.
I0 Amp
in:line
fuse
is blown.
2.
Discharged
battery.
Correction
[.
Reset circuit breaker.
2.
ContactAuthorized
service facility.
3.
Check
and repair.
3.
Failed
battery.
Generator
shuts
down
during
Out
of gasoline.
operation.
Generator
lacks
power.
Load
is too
high.
See
"Don't
Overload
Generator".
4.
Connect
another
device that is in
good condition.
I.
Disconnect
shorted
electrical
load.
2.
See "Don't
Overload
Generator".
3.
ContactAuthorized
service facility.
I.
Replace fuse.
2.
Jump start generator
and/or
charge
battery.
3.
Replace battery.
Fill fuel tank.