Download Print this page
Hide thumbs Also See for 30248:

Advertisement

Available languages

Available languages

Quick Links

0
d
Portabme
Generator/Generador
Port_tii
Model
/ Modeio
030248
CAUTmON
Before
using this product_
read this manuaH and follow
aH
Safety
Relies and
Operating
Instructions.
PRECAUCmON
Antes
de udHizar eH producto_
Hea este
manuaHy
siga todas
Has
Reghs
de Seguridad
e Instrucdones
de Uso.
Questions?
Preguntas?
- 1-888-611-6708
M=F8=SCT
Troy-Bilt®
is a registered
trademark
of HTD
and is used under
license to Briggs & Str_tton
Power" Products.
Troy-BiJt®
es una marca
registrada
de MTD Y se usa abaio
licencia a Brigs
& Stratcon
Power
Products.
BRIGGS
8( STRATTON
POWER
PRODUCTS
GROUP,
LLC
jl
JEF FERSON,W,
SCONS,N,
U.S.A.
s
Printed
in USA
Manual
No. 197584GS
Revision
0 (08/18/2005)

Advertisement

loading

Summary of Contents for Troy-Bilt 30248

  • Page 1 Operating Instructions. Reghs de Seguridad e Instrucdones de Uso. Questions? Preguntas? - 1-888-611-6708 M=F8=SCT Troy-Bilt® is a registered trademark of HTD and is used under license to Briggs & Str_tton Power" Products. Troy-BiJt® es una marca registrada de MTD Y se usa abaio licencia a Brigs &...
  • Page 2 Safety Rules SAVE THESE INSTRUCTIONS TABLE OF CONTENTS SAFETY RULES Section H o Safety Rules ......Section 2 - Features and Controis ....This is the safety amert symbol it is used to Section 3 o Assembiy ......amert you to potentiam personam iniury hazards.
  • Page 3 Section 1: Safety Rules WARNING WARNING WHEN ADDING OR DRAINING FUEL Operate generator ONLY outdoors. through Turn generator OFF and let it cool at least 2 minutes before Keep exhaust gas from entering a confined area windows, doors, ventilation intakes or other openings.
  • Page 4 Section 1: Safety Rules CAUTION WARNING DO NC)T tamper with governed speed_ Generator supplies correct rated frequency and voltage when running at governed WHEN ADJUSTING MAKING REPAiRSTOYOUR speed. GENERATOR DO NOT modify generator in any way: Disconnect the spark piug wh_e from the spark plug and place the vvh_ewhere it cannot contact spark plug.
  • Page 5 Features and Controls KNOWYOUR GENERATOR Read this owner's manual safety rules before operating your generator..Compare the illustrations with your generator, to famiHiarize yourseff with the Hocations of various controHs adjustments. Save this manuaH for future reference. Rocker Switch FueH Tank Recoil Starter Choke...
  • Page 6 ASSEMBLY Install Wheel NOT_:: VVheeH kitisnot intendedforoverothe-road use. Your generator reqores some assembHy and is ready for You will[ need the foHHowing tooHsto install[ these use after it has been properHy serviced with the components: recommended o[Hand fuel ° [/2" or [3mm wrench ff you have any quesqons with the assembHyof your o Socket wrench with a [/2"...
  • Page 7 Section 3: Assembly Fuel Repeat step 4 and 5 to secure second wheel. Tip generator so that engine side is down. NOTE; This gasoline engine is certified to operate gasoline. Exhaust Emission Control System: EM (Engine Line up holes in support leg with holes in generator frame,...
  • Page 8 Operation USmNG GENERATOR System Ground The generator has a system ground that connects the generator frame components to the ground terminals the AC output receptacles,The system ground is connected to the AC neutral wire (the neutral is bonded to the generator frame), Operate...
  • Page 9 Section 4: Operation OPERATmNG WARNING G E N E RATO R Startin the En Disconnect all electrical loads from the generator. Use the following start instructions: Hake sure unit is on a level surface. DO NOT touch hot surfaces and avoid hot exhaust gases. AHow equipment to cool before touching.
  • Page 10 Section 4: Opecat[on G E N E RATO R ADAPTE Engine Turn OFF and unpiug all electricai ioads from generator CORD panel receptacies. NEVER start or stop engine with electricai devices piugged in and turned ON. The generator comes with a 25' generator adapter cord set Let engine run at no:ioad for severai minutes to...
  • Page 11 Section 4: Operation [n an emergency, use the original shipping carton as a For a more permanent shelter, build a structure that will enclose three sides and the top of the generaton Cut off all carton flaps. Hake sure entire muffler-side of generator is exposed_...
  • Page 12 Section 4: Operation DON'T OVERLOAD Plug in and turn on the next load. Again+ permit the generator to stabilize. G E N E RATO R Repeat steps 4 and 5 for each additional load. NEVER add more loads than the generator capacity.Take special care to consider surge loads in generator...
  • Page 13 SPECmFmCATmONS Generat.or Maintenance Generator maintenance consists of keeping unit dean Starting VVattage ....... 5,250 watts dry. Operate store unit in a dean 'Wattage ......3,550 watts environment where it wiHH not be exposed to excessive AC Load Current: dust, dirt, moisture or any corrosive vapors.
  • Page 14 Storage Data tag information is very important if you need help from The generator should be started at least once every seven our Customer Service Department or an authorized service days and allowed to run at Heast 30 minutes. If this cannot dealer.
  • Page 15 TROU B LES H OOT! NG Problem Correction Cause H. One of the circuit breakersis Reset circuit breaker. open. FauHt in generator. ContactAuthorized service fadHity. No AC output is avaHabme, but Poor connection or defective cord Check and repair. generator is running.
  • Page 16 Notes...
  • Page 17 TROYoBILT® OWNERWARRANTY POLICY Effective November m,2004 LiMiTED WARRANTY "TroyoBilt® is a registered trademark of HTD and is used under license to Briggs & Stratton Power Products. Briggs & Stratton Power Products will repair or rephce, free of charge_ any part, or parts of the eqopment _:'_ that are defective in material or workmanship or both.Transpor[ation charges on parts submitted for repair or replacement...
  • Page 18 Reglas de Seguddad CONSERVE ESTAS [NSTRUCCiONES TABLA DE CONTENIDOS REGLAS DE SEGURIDAD Secd6n [ - Reglas De Seguridad ..... 18-20 [_ste es e[ s[mbo[o de aBerta de seguridad. Sirve Secci6n 2 - Caracterisdcas y Controles ....para advertir a[ usuario de un pos[bme riesgo para SeccJ6n 3 - Montaie...
  • Page 19 Secd6n 1: Re [as de Seguddad ADVERTENCIA Opere el generador SOLAHENTE a! aire lible. CUANDO AIgADA COMBUST[BL_: OVAC[E AsegQlese de que los gases de escape no puedan enti_t por ventanas, D_:P6S[TO pue_l:as, tomas de aire de vendJaci6n u ot[_s aberturas en un espacio Apague el genelador (posid6n...
  • Page 20 Secd6n 1: Reglas de Seguddad PRECAUCION ADVERTENCIA NO cambie ninguna velocidad determinada. El generador surninistla una fl ecuencia y un voltaie calificado cuando funciona a una velocidad CUANDO AJUSTE O HAGA REPARACIONE$ A SU detel minada. GENERADOR NO modifique al generado! en ninguna fot ma.
  • Page 21 Caracter[sticas y ControIes CONOZCA SU GENERADOR LEA ESTE MANUAL DEL PROPiETARiOY LAS REGLAS DE SEGURiDADANTES DE OPERAR SU GENERADOR, ..Compare las iJus_raciones con su Generador para farnJiiarizarse con las ubicaciones de los diferentes controles aiustes, Conserve este manual para referencias futuras. [nterruptor ,<.
  • Page 22 Montaje Jnstaie el Juego de Ruedas NOTA: Este ]uego de Ruedas no ha sido dise_ado para set usado Su generador requiere de ciertos procedimientos de montaie y la carter:era. solo estar_ lis_o para ser u_fiizado despu6s de haberle Neceskar_ las siguien_es herramien_as para ins_alar estos suministrado servicio con el combustible 7 aceite recomendados,...
  • Page 23 Secci6n 3: Montaje Repita los pasos de[ 3 a[ 5 para asegurar Ia segunda rueda. Agregue Combustible De[e [a vueka a[ generador de forma que d [ado de[ motor NOTA: Este motor est_ cerdficado para funcionar con gasoJina. quede aba[o. Sistema de controt de emisiones...
  • Page 24 Operad6n GENE DOR Obicaci6n de[ Generador Espacio Libre Amrededor del Generador Tierra de[ $istema EI generador dispone de una conexi6n a _ierra del sistema que conecta los componentes del bas_idor a los _erminales de derra de los enchufes hembra de salida de CA. La derra dd sistema es_ conec_ada aJcame de CA neutro que, a su vez, est_ conectado al basddor...
  • Page 25 Secci6n 4: Operaci6n OPERANDO EL GENERADOR ADVERTENCJA Encienda eJ Motor Desconecte todas las cat,as d6ctrJcas del generado_: Use las sigoentes instrucciones para encender: Aseg@ese de que la unidad esr_ en una superfide plana. JMPORTANTE: Si la unidad no se arranca y utiJiza en una superficb plana, se pueden produdr problemas...
  • Page 26 Secd6n 4: Operaci6n Dem Motor Parado JUEGO DE CABLES ADAPTADOR GENERADOR Desconecte todas Ias cargas el_ctricas de los tomacorrientes deJ panel deJ generation NUNCA de arranque o detenga el El generador est_ equipado con un Juego de Cables det Adaptador motor con todos los dispositivos el6ctricos...
  • Page 27 $ecci6n 4: Operaci6n Para una protecci6n m_s permanente, construya una estructura En caso de emergencia, udlice la caja de cart6n del embalaie oMginal como una protecci6n temporak que rodee Ios tres lados y la parte superior dd generador. Corte Ias tapas de Ia caia. Aseg@ese de que quede expuesto el Iado completo...
  • Page 28 Secd6n 4: Operad6n NO $OBRECARGUE GENERADOR Conecte y encienda la pr6xima carga. De nuevo, permita que el generador se estabilice. Capacidad Repita los pasos 4 y 5 para cada carga adicionaI que usted tenga. Usted debe asegurarse que su generador puede proveer el NUNCA afiada mM cargas...
  • Page 29 ESPEC(F(CAC(ONES NOTA: recomendamos el uso de mangueras de jardin para limpiar e[ generador. El agua podria introdueirse en el sistema de Vataje que empieza ....5,250Vados (5.25 kVV) combustible del motor y eausar probJemas.Adem_s, si el agua se Vataje ......3,550Vados (3.55 kW) introduce...
  • Page 30 Ilene este de gasolina nueva. Haga funcionar la unidad durante Troy-Bilt® is a registered trademark MTD and is used under license to varios minutos para que el aditivo circule a trav6s deJ Bdggs & Stratton carburador.
  • Page 31 Diagnosticos de Aver as DmAGNOSmTmCOS DE AVERJAS Action Probiemo Causa El interruptor au_om_.tico de circoto Reposicione et incerruptor. est,. abJerto. Revise y repare. Conexi6n real o defecmosa det iuego de cables_ El motor est5 funcionando pero e×iste sa_ida de AC disponsibJe. Conec_e otto dispos_two que est6 El dispositivo conectado...
  • Page 32 POLiTiCA PARA EL PROPiETARIO DE EQUiPOSTROY=BiLT® Efecdva desde [ ro de Noviembre, 2004 GARANTiA LiMiTADA "Troy_BiJt® es una marca registrada de MTD baio licencia de Briggs & Stratton Power Products. Briggs & Stratton Power Products reparar_ o susdtor_ sin cargo atguno cualquier componente del eqopo** que presente defectos...