04. VOLUME
Gain Data
Function
The external control equipment changes theVOLUME gain data oftheplasma
monitor.
Transmission Data
DATA00: USER SOUND GainFlag
05H
DATA01:VOLUMEGain F lag
0IH
DATA02:VOLUME Gain
00H:Step0
OAH: S tepI0 (Default)
ACK
2AH:Step42
DATAOO: USER SOUND GainFlag
05H
DATAOl: VOLUME GainFlag
0IH
05. AUDIO Mute On
Function
The external control equipment switches onAUDIO M ute ofthe plasma monitor.
Transmission Data
ACK
06. AUDIO Mute Off
Function
The external control equipment switches off A UDIO Mute ofthe plasma monitor.
Transmission Data
ACK
07. CONTRAST
Gain Data
Function
The external control equipment changes the CONTRAST
gain data ofthe plasma
monitor.
Transmission Data
DATA00: USER PICTURE G ainFlag
0IH
DATA01: CONTRAST GainFlag
07H
DATA02: CONTRAST Gain
CCH:-52
FFH:-Ol
00H:0
0IH:+Ol
I4H:+20
ACK
DATAO0:USER PICTURE G ainFlag
0IH
DATAOI: CONTRAST GainFtag
07H
08. BRIGHT Gain Data
Function
The external control equipment changes theBRIGHT gain data oftheplasme
monitor.
Transmission Data
DATA00: USER PICTURE G ainFlag
0IH
DATA01: BRIGHTGain F lag
08H
DATA02: BRIGHT G ain
EOH:-32
ACK
FFH:-01
00H:0
0IH:+0I
20H:+32
DATAO0:USER PICTURE G ainFlag
0IH
DATAOI: BRIGHTGain F lag
08H
09. SHARPNESS
Gain Data
Function
Theexternal control equipment changes theSHARPNESS
gaindata ofthe
plasma m onitor.
Transmission Data
DATAO0:USER PICTURE G ainFlag
0IH
DATAOI: SHARPNESS GainFlag
06H
DATA02: SHARPNESS Gain
FOH:-16
OnlywhenaRGBsignalis connected
DATA02: SHARPNESS Gain
ACK
FFH:*01
00H:0
0IH:+0I
IOH:+I6
0IH:1
02H:2
03H:3
04H:4
05H:5
DATAO0:USER PICTURE G ainFlag
DATAOI: SHARPNESS GainFlag
0IH
06H
43