Line-Up & Trim Out; Plumbing - Hill Phoenix KRZH Installation & Operation Handbook

Frozen food/ ice cream cases, kats kold air technology system
Table of Contents

Advertisement

The drain outlet is located front and
center of the cases for convenient access.
The drain outlet on the KRZH is molded out of
ABS material.
The "P" trap, furnished with
the case, is constructed of schedule 40 PVC
pipe. Care should be given to assure that all
connections are water tight and sealed with
the appropriate PVC cement, ABS cement, or
pipe dope.
The lines can be run left or right of the
tee with the proper pitch to satisfy local
drainage requirements.
44 5/8 in
[113.3 cm]
case for field installation, therefore you should
have open access to the drain line area. If the
kickplate has been installed, you will find it
very easy to remove. See instructions below,
or the line-up and trim out section of this manual
on page 7.
19 5/8 in. [49.8 cm.] {2-DOOR}
34 5/8 in. [87.9 cm.] {3-DOOR}
49 5/8 in. [126.0 cm.] {4-DOOR}
64 5/8 in. [164.1 cm.] {5-DOOR}
20 3/4 in
[52.7 cm]
**
C L
FRONT OF CASE
60 in. [152.4 cm.] {2-DOOR}
90 in. [228.6 cm.] {3-DOOR}
120 in. [304.8 cm.] {4-DOOR}
150 in. [381.0 cm.] {5-DOOR}
NOTES:
* STUB-UP AREA
** RECOMMENDED STUB-UP CENTERLINE FOR ELECTRICAL AND HUB DRAINS
MODEL
KRZH
HOW TO REMOVE KICKPLATE
LIFT UP FROM "J" RAIL
AND PULL OUT
KICKPLATE
"J" RAIL
9

PLUMBING

The kickplate is shipped loose with the
EXTERNAL PLUMBING
11 7/16 in [29.1 cm]
2 13/16 in [7.1 cm]
1 1/2" PVC DRAIN
CONNECTION
39 1/8 in
44 5/8 in
[99.4 cm]
[113.3 cm]
42 7/16 in
[107.8 cm]
1 1/2 in [3.8 cm]
{END}

Advertisement

Table of Contents
loading