ELECTRICAL HOOKUP
Electrical hookups are made to a
junction box located at the top, left of the
case. For case-to-case wiring, run "green-
field", or other conduit, between junction
boxes.
34 1/4 in
[87.0 cm]
44 5/8 in
[113.3 cm]
7 13/16 in
[19.9 cm]
WIRING NUMBERS AND COLORS
COMPONENT
EVAPORATOR FANS, 120 VOLT
DOOR & FRAME ANTI-COND. HEATERS, 120 VOLT
LIGHTS, 120 VOLT
ANTI-CONDENSATE HEATERS, 120 VOLT
TEMPERATURE CONTROL, 120 VOLT
DEFROST TERMINATION CONTROL, 120 VOLT
DEFROST HEATERS, 208/240 VOLTS
EQUIPMENT GROUNDING CONDUCTOR
20 3/4 in
[52.7 cm]
**
ELECTRICAL
(TOP OF CASE)
FRONT OF CASE
60 in. [152.4 cm.] {2-DOOR}
90 in. [228.6 cm.] {3-DOOR}
120 in. [304.8 cm.] {4-DOOR}
150 in. [381.0 cm.] {5-DOOR}
NOTES:
* STUB-UP AREA
** RECOMMENDED STUB-UP CENTERLINE FOR ELECTRICAL AND HUB DRAINS
MODEL
KRZH
WIRE NUMBER
3
4
15
16
11
12
13
14
19
20
21
23
L1
L2
-
When connecting to the junction box
on the bottom left side of the case, field
wiring should exit the junction box from the
right hand side, furthest away from case
wiring, increasing room inside for wire con-
necting.
C L
ELECTRICAL ACCESS HOLE
COLOR CODING
(Drilled through rear of case)
WHITE
BLACK
WHITE
BLACK
WHITE
BLACK
WHITE
BLACK
YELLOW
YELLOW
PURPLE
ORANGE
RED
BLUE
GREEN
10
44 5/8 in
[113.3 cm]
42 7/16 in
[107.8 cm]
1 1/2 in [3.8 cm]
{END}