J. Control Module Operation
1. The control module has an ON/OFF/REMOTE selector
switch that must be set. See Figure 2.3.
OFF Position: Appliance will ignore all power inputs and
will not respond to any commands from a wall switch or
remote. The unit should be in the OFF position during
installation, service, battery installation, fuel conversion,
and in the event that the control goes into LOCK-OUT
mode as a result of an error code.
ON Position: Appliance will ignite and run continuously
in the HI flame setting, with no adjustment in flame
output. This mode of operation is primarily used for
initial installation or power outage operation with battery
backup.
REMOTE Position: Appliance will initiate commands
from an optional wired wall switch and/or the wireless
remote (RC300AU).
2. If using a wired wall switch with the module in REMOTE
mode, the flame output can be adjusted with the HI/
LO selector switch on the module. See Figure 2.3.
Note that the flame HI/LO selector switch will become
inactive once an optional remote control (RC300AU) is
programmed to the control module. Note that the control
module will always ignite the fireplace on HI and remain
so for the initial 10 seconds of operation. If the HI/LO
is switched to the LO position, the flame output will
automatically drop to the lowest setting after the flame
has been established for 10 sec. After this 10 second
period, the flame can be adjusted from HI to LO with
the switch.
3. The control module has safety feature that automatically
shuts down the fireplace after 9 hours of continuous
operation without receiving a command from the
RC300AU remote.
4. If you intend to use both an optional wired wall switch
and the RC300AU remote control to operate your
fireplace, the wall switch will override any commands
given by the remote.
5. The module has the capability to recognize potential
malfunctions. If these occur, it will fail to ignite and/
or respond to a command to ignite via the wall switch
and/or remote. In this case, the module may have
gone into LOCK-OUT mode. In this state, it will emit
a LED error code. To reset the error code, switch the
selector to OFF, and then back to REMOTE or ON. If
the ignition command again fails, the module will emit
an LED error code, prior to going back into LOCK-OUT
mode. Contact your dealer for service if this occurs.
Note: If the module is in LOCK-OUT mode, resetting the
circuit breaker to the appliance will also reset the module.
Note: For units installed in Australia, the residence's 220/240
wall outlet to which this appliance's power cord is connected,
must be wired to an in-line on/off switch. This is required for
servicing and/or resetting the control module in the event of
a control module LOCK-OUT.
14
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/13
MODULE
FLAME HI/LOW
STATUS
SWITCH
INDICATOR LED
Figure 2.3 Control Module
Nine Hour Safety Shutdown Feature
This appliance has a safety feature that automatically
shuts down the fireplace after 9 hours of continuous
operation without receiving a command from the wall
switch or RC300AU remote.
SELECTOR
SWITCH
NG/LP GAS-TYPE
SELECTOR SWITCH