Meridian 502 User Manual page 25

Analogue controller
Hide thumbs Also See for 502:
Table of Contents

Advertisement

Use the A and V keys to change the sensitivity.
For example, the display will show:
Switch between the source you are changing and the
reference source until they sound equally loud.
Repeat the procedure for your other sources.
When you have finished programming levels, switch the
power off and on again to restore the analogue controller to
normal operation.
If you know the output level of your sources you can probably
set the gains by calculation. The following table shows the
correspondence between the gain and sensitivity on the
L P
- 4 d B
standard audio inputs and on the LP inputs:
Gain
-15dB
-10dB
-5dB
0dB
5dB
10dB
15dB
A2-A7
LP MM
840mV
17mV
470mV
9.5mV
270mV
5.3mV
150mV
3mV
84mV
1.7mV
47mV
950 V
27mV
530 V
LP MC
1.2mV
660 V
380 V
210 V
120 V
66 V
38 V