GE Profile 42 Owner's Manual And Installation Instructions page 47

Built-in side by side refrigerators
Table of Contents

Advertisement

Available languages

Available languages

Performance
Data Sheet
smartwater
Filtration System
GWF / HWF Cartridge
This system has been tested according to NSF/ANSt 42/53 for reduction of the substances listed below.
The concentration
of the indicated substances in water entering the system was reduced to a concentration
less than or equal to the permissible
limit for water leaving the system,
as specified
in NSF/ANSI 42/53.*
(100% safety factors built in for unmetered
usage)
Standard
No, 42: Aesthetic
Effects
Parameter
Chlorine
T&O
Particulate**
USEPA
MCL
Influent
Challenge Concentration
20 mg/L + 10%
at least 10,000 particles/mL
Emue_
Average
Maximum
002ppm
005ppm
3,978
7,800
Standard
No. 53: Health Effects
Parameter
USEPA
MCL
1 NTU***
9995% Reduction
15 ppb
15 ppb
00002 ppm
0003 ppm
0100 ppm
99%
% Reduction
Average
Minimum
9890%
9737%
9800%
9610%
Influent
Challenge Concentration
11 + 1 NTU***
Minimum 50,000 L
015 mo_L+ 10%
015 mo_L+ 10%
0002 mg/L + 10%
0009 mg/L + 10%
0210 mg/L + 10%
107to 10ofibors/L;
fibors greotor than
10 micrometers in length
Effluent
Average
Maximum
007 NTU
O1 NTU
26
5S
i ppb
I ppb
18 ppb
43 ppb
000005 ppm
000005 ppm
0002 ppm
0003 ppm
0042 ppm
0090 ppm
032 MFUml
12 MFUml
Turbidity
9959%
Cysts
9995%
read at pH 65
9937%
Leadat pH 85
9713%
Undone
9193%
Abazine
6428°6
2,Z_D
6763%
Asbestos
9982%
% Reduction
Average
Minimum
9971%
9997%
9937%
988%
9193%
7619%
8_89%
9995%
* Tested using o flow rote of 0.5 gpm; pressure of 60 psig; pH of 7,5 +_0.5; temp. of 20 ° +_2,5°C
** Measurement in Particles/at
Particles used were 0,5-1 microns
*** NTU=Nephelometric Turbidity units
Min. Required
Reduction
> 50%
>85%
Min. Required
Reduction
05 NTU
> 9995%
OO10mo_L
OO10m_L
00002 mg/L
0003 ma_L
007 mg/L
99%
Operating
Specifications
•Capacitg: certified for up to 500 gallons (1135 I);up to twelve months for all models
• Pressure requirement: 40-120 psi (2.8-8.2 bar), non-shock
• Temperature:
33-100°F
(0.6-38°C}
Flow rate:
0.5 gpm
(1.9 Ipm}
General
Installation/Operation/Maintenance
Requirements
• Flush new cartridge at full flow for 3 minutes to purge out trapped air.
• Replace cartridge when flow becomes too slow.
Special
Notices
• Installation
instructions,
parts and service availabilitg,
and standard
warrantg
are included with the product when shipped.
• This drinking water sgstem must be maintained
according
to manufacturer's
instructions,
including
replacement
of filter
cartridges.
• Do nat use with water that is microbiologicallg
unsafe or of unknown
qualitg without
adequate
disinfection
before
or after the sgstem. Sgstems certified for cgst reduction
mag be used on disinfected
water that mag contain filterable
cgsts.
• The contaminants
or other substances
removed or reduced bg this water treatment
sgstem are not necessarilg
in gour waten
• Check for compliance
with the state and local laws and regulations.
• Note that while the testing was performed
under standard
laboratorg
conditions,
actual performance
mag varg. Sgstems
must be installed
and operated
in accordance
with manufacturer's
recommended
procedures
and guidelines.
Standard
No. 42: Aesthetic
Effects
Chemical
Unit
Taste and Odor
Reduction
Chlorine
Reduction
Mechanical
Filtration
Unit
Particulate
Reduction,
Class I
Standard No. 53: Health Effects
Chemical Reduction Unit
Lead and Atrozine Reduction
Und(]ne and 2,4-D Reduction
Mechanical Fi}trotion Unit
Turbidity Reduction
Cyst and Asbestos Reduction
Manufactured for: General Electric Company, Louisville, KY90225
47

Advertisement

Table of Contents
loading

This manual is also suitable for:

Profile 48

Table of Contents