Installation
Instructions
INSTALLATI 0 N-R ECIRCU LATING
STEP 9 CONNECT ELECTRICAL
Verify that power is turned
off at the source.
-_ WARNING:
ifhouse wiringisnot 2-wire
with o ground wire, o ground must be provided
by the instoller,
When house wiringis oluminum,
be sure to use U,L, opproved onti-o×idont
compound
ond oluminum-to-copper connectors,
• Remove the 6 screws on thejunction box cover
ond the knockout on the top left s ide,
Knockout
Junction __-_-\
• Secure the house wiring to the junction
box with
o stroin relief (not provided).
f
C
S
• Connect the white leod to the bronch circuit white leod.
• Connect the block leod to the bronch circuit block leod.
• Connect the green/yellow
leod to the bronch
circuit green leod or bore ground leod.
• Secure oll the connections
with wire nuts on eoch
electricol
connector.
• Push the wires into the junction
box ond reploce
the cover. Be sure the wires ore not pinched.
• Secure the junction
box cover with the 6 originol
screws.
[STEP i0] INSTALL DUCT COVER SUPPORTS
• Attoch the duct cover supports to the sides
of the horizontml rand ceiling supports
using
4 screws per duct cover support.
Ceiling
SU
Horizontal
SU
Screws
Duct cover
support