Section 4: wiring

ON / OFF
ON/OFF
Battery
Holder
4 x 1.5V
AA Type
Red
Black
BATTERY
120 Vac INPUT
7 Vdc STABILIZED
DC SUPPLY
SUPPLY OUTPUT
'Hi-Lo' Adjustment Knob
Manifold Pressure
Test Connection
Inlet Pressure
Gas Control Knob (Shown in "Pilot" position)
Figure 21. Wiring Diagram for SIT nova 820 gas and pilot.
XG0146 - 050211.1
Installation
(CPI / IPI MODE
Not Used)
IPI/CPI
GROUND
Figure 20. Wiring Diagram for the SIT Proflame Electronic Ignition
Models
H34DFn
HC34DFn
HR34DFn
H34DFL
HC34DFL
Power
Pilot Adjustment Screw
Generator
Wall Switch
Green
Orange
880 Valve
VALVE
Chassis
connection
Honeywell (Q3450)
Pilot Assembly
Gas Control
Connector
Fan Plug
Receptacle
Gnd Screw
Wall Switch
Figure 22. Wiring Diagram for Honeywell gas control and pilot.
H*34DF Indoor Gas Fireplace
Models
H34DFnI
HL34DFnI
H34DFLI
HL34DFLI
HC34DFnI
HR34DFnI
HC34DFLI
DFC
Models
H34DFnE
H34DFLE
HC34DFnE
Pilot Electrical
Harness Connector
HC34DFLE
Honeywell Gas
Control (SV9501M)
Junction Box
115VAC
24VAC
40 VA
Transformer
Black
White
Green
Page 17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hc34dfHl34dfHr34df

Table of Contents