Figure 8c - Attaching Upper Switch
Housing to Switch Housing Mounting
Plate
ATTACHING THE UPPER SWITCH
HOUSING
1. Locate the four #6-32 X 1/4"
switch housing mounting screws
in the sack parts.
2. Feed the upper plug connector
through the center hole in the
upper switch housing.
41557-01 3/12/2002
3. Align the holes in the upper
switch housing with the spokes
in the mounting plate.
4. Insert and tighten the four #6-32
X 1/4" screws into the outermost
holes in the upper switch hous-
ing.
CAUTION
Make sure the upper switch
housing is securely attached to
the switch housing mounting
plate. Failure to properly at-
tach and tighten all four hous-
ing assembly screws could re-
sult in water entry into live con-
nection area and/or the switch
housing and light fixture falling.
ATTACHING THE LOWER
SWITCH HOUSING/LIGHT AS-
SEMBLY
1. Locate the four #6-32 X 3/8"
housing screws.
NOTE: Depending upon your fan
model, these screws may be in-
stalled in the four spokes from
the switch housing mounting
plate, or they may be located in
the sack parts.
2. Install the screws halfway into the
four spokes from the switch hous-
ing mounting plate.
See Figure 8d.
NOTE: if these screws came in-
stalled, make sure that they are
installed halfway in order to
complete the following steps.
3. Connect the upper plug connec-
tor to the lower plug connector
®