Download Print this page
Pullman Holt 102ASB-12P Operation & Care Instructions

Pullman Holt 102ASB-12P Operation & Care Instructions

Wet/dry asbestos vacuum cleaner

Advertisement

Quick Links

Model 102ASB-12P
Wet/Dry Asbestos Vacuum Cleaner
This vacuum cleaner is a high quality, precision made product. All
parts used in the manufacturing of this vacuum cleaner have passed
rigid quality control standards prior to assembly and an "each unit"
final inspection prior to packaging is your assurance of proper
assembly. This vacuum cleaner was protectively packed to prevent
possible damage in transit. Should damage occur, please notify the
transporting carrier immediately for loss and/or claim.
MOTOR:
The suction head of this vacuum cleaner is equipped with a 2 stage,
11.1 amp, 2HP by-pass motor, developing 105" waterlift and 110
CFM.
When removing the motor head, care in handling is essential.
Dropping, banging or other abuse may result in poor vacuum seal
and a loss in suction power and will invalidate your warranty.
Operation & Care Instructions
Save For Future Reference

IMPORTANT SAFEGUARDS

EXTENSION CORDS:
Vacuums that have 3 wire cords requiring grounding must only be
used with extension cords that have 3-prong grounding type plugs
and 3-pole receptacles.
To determine the minimum wire size required, refer to the chart
below:
Minimum Wire Size (AWG) of Extension Cord
Nameplate
Total Extension Cord Length (Feet)
Rating-Amps
25
50
0-10.0
18
18
10.1-13.0
16
16
13.1-15.0
12
12
Before using an extension cord,inspect it for loose or exposed wires,
damaged insulation and defective fitting.
CAUTION
Always disconnect power cable from outlet when working
on this vacuum.
75
100 125 150 175 200
16
16
14
14
12
14
14
14
12
12
12
12
12
12
12
12
12

Advertisement

loading

Summary of Contents for Pullman Holt 102ASB-12P

  • Page 1: Important Safeguards

    Operation & Care Instructions Save For Future Reference Model 102ASB-12P Wet/Dry Asbestos Vacuum Cleaner This vacuum cleaner is a high quality, precision made product. All parts used in the manufacturing of this vacuum cleaner have passed rigid quality control standards prior to assembly and an “each unit” final inspection prior to packaging is your assurance of proper assembly.
  • Page 2: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS IMPORTANTES MESURES DE SÉCURITÉ L’utilisation d’un appareil électrique demande certaines précau- When using an electrical appliance, basic precautions should tions: always be followed, including the following:. LIRE TOUTES LES INSTRUCTIONS AVANT DE READ ALL INSTRUCTIONS FAIRE FONCTIONNER CET APPA R E I L BEFORE USING THIS VACUUM CLEANER AVERTISSEMENT: WARNING...
  • Page 3: Grounding Instructions

    GROUNDING INSTRUCTIONS INSTRUCTIONS VISANT LA MISE À LA T E R R E This appliance must be grounded. If it should malfunction or Cet appareil doit être mis à la terre. En cas de défaillance ou de breakdown, grounding provides a path of least resistance for elec- panne éventuelles, la mise à...
  • Page 4: Limited Warranty

    ABOUT THE MACHINE FOR DRY OPERATION: VACUUM ASSEMBLY GUIDE: 1. Remove and carefully set aside motor head and HEPA filter. 2. Position 8” rear wheels and insert 3/8” x 3 1/4” mounting bolts through the wheel and frame. Secure with 3/8” lock nuts. 2-HP By-Pass Motor 3.