Download Print this page

Limited Warranty - Pullman Holt 102ASB-12P Operation & Care Instructions

Wet/dry asbestos vacuum cleaner

Advertisement

VACUUM ASSEMBLY GUIDE:
1. Remove and carefully set aside motor head and HEPA filter.
2. Position 8" rear wheels and insert 3/8" x 3 1/4" mounting bolts
through the wheel and frame. Secure with 3/8" lock nuts.
3. Insert and push casters into the holes located at the front of the
vacmobile metal frame.
4. Lock the casters in place with the hub nuts, using a rubber
hammer.
5. Replace motor head and filter.
CAUTION
Always disconnect power cable from outlet when working on
this vacuum.
FOR WET OPERATION:
2-8 " Wheels
With HEPA filter and water pick-up pan in place, securely clamp
motor head to the spacer. When the maximum water level in the
vacuum cleaner polytank is reached the water pick-up pan's safety
valve (float) closes off suction, automatically preventing further
liquid intake.
NOTE: This will cause the motor to race. Turn off motor, remove
and empty poly tank. Thoroughly clean float assembly.
Replace water pick-up adapter, HEPA filter and motor head,
then clamp securely. The vacuum cleaner is ready for wet
use.
The vacuum motor is warrantied for 1 year and other parts except fil-
ters for 90 days from the date of purchase as shown on your
distributor's invoice.
The warranty covers only failure due to
defective parts or workmanship and will be invalidated by improper
application and abusive damage.
ABOUT THE MACHINE
2-HP By-Pass Motor
Spacer with
HEPA Filter System
Water Pick-Up Pan
12-Gallon Recovery
Polyethylene Tank
2-2 1/2 " Casters

LIMITED WARRANTY

10702 N 46th Street • Tampa, FL 33617
(813) 971-2223 • fax (813) 971-6090
www.pullman-holt.com
FOR DRY OPERATION:
2-8 " Wheels
With the HEPA Filter Assembly in place, the motor head securely
clamped,and the metal hose adapter connected to the inlet,plug the
power cable into the proper outlet. Select the appropriate hose,
wand and/or tool and connect to the hose adapter. The vacuum
cleaner is ready for dry use.
DISPOSABLE BAG CHANGING:
Over filling the bag will result in loss of vacuum efficiency. The rec-
ommended bag replacement procedure is as follows:
1. Remove vacuum head and HEPA filter.
2. Tape a 6-mil poly bag over the canister so that the canister is
completely enclosed.
3. Using the poly bag as a glove,disengage the paper bag from the
vacuum inlet stem inside the canister.
4. Invert the canister so that the paper bag falls into the poly bag.
Seal the poly bag and dispose as prescribed by law.
5. Attach a new paper bag to the vacuum inlet securely and fold the
top of the bag down so it does not interfere with the HEPA filter.
6. Replace the HEPA filter and motor head.
7. Thoroughly vacuum the work area to recover any asbestos dust
which may have been dropped.
CAUTION
When removing the motor head,care in handling is essential. Dropping,
banging or other abuse may result in poor vacuum seal and a loss in
suction power, and will invalidate your warranty.
In NO circumstance should you return a failed unit to the factory of a
service center.
If you experience any problems with your vacuum during the
warranty period, contact the Pullman-Holt National Service Manager
in Tampa, FL at (800)237-7582.
2-HP By-Pass Motor
HEPA Filter System
Paper Collector Bag
12-Gallon Recovery
Polyethylene Tank
2-2 1/2 " Casters
B700334 01/10