Logging Function

With Record/Measure you can start the logging (recorder) function or you can
get back into the measuring mode. Before the start, maximum recording time is
indicated and you can change this value with cursor.
Changes in the averaging time, cause corresponding changes in the recording
time of the measurement (double averaging time = double recording time).
When the recorder graphics reach the screen margin during recording, a picture
of this screen is saved.
The display is then deleted and the recording is continued. Up to 6 auto screens
are saved in the course of a recording. The saved screenshots can be retrieved
via the View Auto Screenshots menu.
Do not forget to operate the Logger with the BC 1735 AC Power
Adapter during recording in order to prevent shutdown caused by low
battery.
Active and reactive energy are not shown in the recorder function.
Note