Electrical Requirements - Whirlpool ACE184XR0 Use & Care Manual

Hide thumbs Also See for ACE184XR0:
Table of Contents

Advertisement

Available languages

Available languages

Window
installation
Window opening measurements:
261/2 '' (66.1 cm) minimum to 40" (101.6 cm) maximum
opening width.
20" (50.8 cm) minimum opening height.
1
A C
B
h
A. 26 _" (66.1cm) minimum
B. 20" (50.8 cm) minimum
Through-the-wall
installation
The wall opening measurements should be:
Width: 261/2 '' (66.1 cm) plus twice thickness of wood used to
build frame.
Height: 193/4 '' (50.2 cm) plus twice thickness of wood used to
build frame.
C
A. 19_" (50.2 cm)
B. 26 _" (66.1 cm)
t
C
C. Wood thickness
E_ectdca_
Shock
Hazard
Plug into a grounded
3 prong
outlet.
Do not remove
ground
prong.
Do not use an adapter.
Do not use an extension
cord.
Failure
to follow
these
instructions
can result
in
death,
fire,
or electrica_
shock.
Ground wire must be connected to ground screw located in lower
right corner of air conditioner
when air conditioner
is in cabinet.
The electrical ratings for your air conditioner
are listed on the
model and serial number label. The model and serial number
label is located behind the front panel on the flange below the
control panel area.
Specific electrical requirements are listed in the chart below.
Follow the requirements for the type of plug on the power supply
cord.
Power supply cord
Wiring requirements
115 volt (103.5 min. -
(_
126.5 max.)
0-12 amps
15-amp time-delay fuse or
circuit breaker
Use on single outlet circuit only.
230 volt (207 min. - 253 max.)
1/4"
(o.6ore)
0-12 amps
_
_
15-amptime-delayfuseor
circuit breaker
Use on single outlet circuit only.
230 volt (207 min. - 253 max.)
0-16 amps
20 amp time-delay fuse or
circuit breaker
Use on single outlet circuit only.
230 volt (207 min. - 253 max.)
1/2"
(1.3 cm)
0-24 amps
_
_
30 amp time-delay fuse or
circuit breaker
Use on single outlet circuit only.