Whirlpool ACE184XR0 Use & Care Manual page 18

Hide thumbs Also See for ACE184XR0:
Table of Contents

Advertisement

Available languages

Available languages

Air conditioner
power supply cord trips (Reset button
pops out)
Disturbances
in your electrical current can trip (Reset
button will pop out) the power supply cord. Press and
release RESET (listen for click; Reset button will latch and
remain in) to resume operation.
An electrical overloading, overheating,
pinching or aging
can trip (Reset button will pop out) the power supply
cord. After correcting the problem, press and release RESET
(listen for click; Reset button will latch and remain in) to
resume operation.
NOTE: A damaged power supply cord must be replaced with a
new power supply cord obtained from the product manufacturer
and must not be repaired.
Air conditioner
seems to run too much
The current air conditioner
replaced an older model. The
use of more efficient components
may cause the air
conditioner to run longer than an older model, but the total
energy consumption
will be less. Newer air conditioners
do
not emit the "blast" of cold air you may be accustomed
to
from older units, but this is not an indication of lesser cooling
capacity or efficiency. Refer to the efficiency rating (EER) and
capacity rating (in BTU/hr.) marked on the air conditioner.
The air conditioner is in a heavily occupied room, or heat-
producing appliances are in use in the room. Use exhaust
vent fans while cooking or bathing and try not to use heat-
producing appliances during the hottest part of the day. A
higher capacity air conditioner
may be required, depending
on the size of the room being cooled.
Air conditioner
cycles on and off too much, or does not
cool/heat
room in cooling/heating
mode
The Mode or Fan control is set to Power Saver (on some
models). Use Power Saver only when you are asleep or away
from home, since the fan does not circulate the room air
continuously. Use Low Cool, High Cool or Turbo Cool for your
best comfort.
The air conditioner is not properly sized for your room.
Check the cooling capabilities
of your room air conditioner.
Room air conditioners
are not designed to cool multiple
rooms.
The filter is dirty or obstructed
by debris. Clean the filter.
The inside evaporator
and outside condenser
coils are
dirty or obstructed by debris. See "Annual Maintenance."
There is excessive heat or moisture (open container
cooking, showers, etc.) in the room. Use a fan to exhaust
heat or moisture from the room. Try not to use heat-
producing appliances during the hottest part of the day.
The louvers are blocked. Install the air conditioner
in a
location where the louvers are free from curtains, blinds,
furniture, etc.
The outside temperature
is below 65°F (18°C). Do not try to
operate your air conditioner in the cooling mode when the
outside temperature is below 65°F (18°C).
The temperature
of the room you are trying to cool is
extremely
hot. Allow extra time for the air conditioner to cool
off a very hot room.
Windows
or doors to the outside are open. Close all
windows and doors.
The Vent control
is set to OPEN (on some models). Push
the Vent control to CLOSED for maximum cooling and/or
heating.
The temperature
set point or Thermostat
control is not at
a cool enough setting. Adjust the temperature set point to a
cooler setting by pressing the minus button to reduce the
temperature or adjust the Thermostat control to a cooler
setting by turning the knob clockwise. Turn the Fan control to
Turbo Cool.
The air contitioner in the heating mode has insufficient
BTU/hr for the heating requirements of the room. Do not
use the air conditioner
as a primary source of heat.
Water drips from cabinet into your house
The air conditioner is not properly
leveled. The air
conditioner
should slope slightly downward toward the
outside. Level the air conditioner to provide a downward
slope toward the outside to ensure proper drainage. See the
Installation Instructions.
NOTE: Do not drill a hole in the bottom of the metal base and
condensate
pan.