Command/Response Table For Special Function Sis Commands - Extron electronics System 7SC User Manual

System switcher
Table of Contents

Advertisement

Serial Communication, cont'd
The syntax for setting a special function is __ *
To view a function's setting, use __#, where __ is the function number. In the following table the values of
the
variable are different for each command/function. These values are given in the rightmost column.
X?

Command/response table for special function SIS commands

Command
Delay times
Power on delay
Example:
Example:
Power off delay
Example:
RGB delay
(Triple-Action Switching)
Example:
Room relays
Room relay 1 mode/timing
Example:
Room relay 2 mode/timing
Example:
Scaler settings
Scaler output sync format
Example:
Scaler output polarity
Example:
Blue screen
(blue & sync output only)
Example:
4-8
System 7SC • Serial Communication
# where __ is the function number and
X?
ASCII Command Response
(host to switcher)
(switcher to host)
1 *
#
WarmUp*
X?
1*8#
WarmUp*08
1#
WarmUp*023
2 *
#
CoolDown*
X?
2*23#
CoolDown*023
3 *
#
RGBDly*
X?
3*7#
RGBDly*07
4 *
#
Rly1Tm*
X?
4*15#
Rly1Tm*15
5 *
#
Rly2Tm*
X?
5*8#
Rly2Tm*08
6 *
#
SyncOut*
X?
6*1#
SyncOut*1
7 *
#
SyncPol*
X?
7*1#
SyncPol*1
8*
#
Blu*
X?
X?
8*1#
Blu*1
values
X?
and additional descriptions
0 = 0 seconds,
X?
1 = 2 seconds,
2 = 4 seconds,
... in 2 second steps up to
150 = 300 seconds (5 minutes).
Example: set a 16 second power on delay
Example:
view the power on delay
setting.
0 = 0 seconds,
X?
1 = 2 seconds,
2 = 4 seconds,... in 2 second
steps up to 150 = 300 seconds.
Example:
set a 46 second power off
delay.
0 = 0.0 seconds (default), 1 = 0.5
X?
seconds, 2 = 1.0 seconds,
... in ½ second steps up to
10 = 5.0 seconds
Example: 3.5 second RGB delay
0 = toggle mode (press on/off),
X?
1 = momentary,
2 = momentary, ¼ second long,
3 = momentary,
... in
1
second steps up to
/
8
16 = 2.0 seconds
Example:
momentary, 1.875 sec. long
0 = toggle mode (press on/off),
X?
1 = momentary,
2 = momentary, ¼ second long,
3 = momentary,
... in
1
second steps up to
/
8
16 = 2.0 seconds
Example:
momentary, 1.0 sec. long
0 = RGBHV (default)
X?
1 = RGBS
2 = RGsB (sync on green, SOG)
Example: RGBHV sync output
0 = H-/V- (default)
X?
1 = H-/V+
2 = H+/V-
3 = H+/V+
Example: H-/V+ sync polarity
0 = off
(default) (RGB & sync output)
1 = on
(blue video & sync output only)
Example:
blue & sync output for setup
is the value.
X?
1
second long,
/
8
second long,
3
/
8
second long,
1
/
8
3
second long,
/
8

Advertisement