Remote Control From A Network; Enabling Remote Control Of The Switcher Over A Network - Extron electronics SWP123 User Manual

Extron electronics presentation switchers user's manual swp123
Table of Contents

Advertisement

Remote Control, cont'd
Command
Enable/disable microphone talk over
[MTOx]
Talk over recovery time
[MLAGx]
Program audio ducking amount adjustment
[MRAMPx]

Remote Control from a Network

You can control the SWP123 switcher from a remote location across a Local Area
Network (LAN), a Wide Area Network (WAN), or over the Internet.
This remote network control is available in a client-server environment, where
the PC attached to the switcher is called the server, and the PC that needs to
control the device from another location is called the client.

Enabling remote control of the switcher over a network

Both the user operating the client (remote PC) and the user operating the server
(local PC) must install the ICS100 Control Software program onto their respective
PCs. See chapter 4, Windows-Based Control Program, for information on installing
the software. The following sections describe how to configure the server and
client PCs.
SWP123 Presentation Switcher • Remote Control
5-8
Description
Sets microphone talk-over state.
x = 0 to disable microphone talk over; 1 to enable
microphone talk over.
x = ? to request current state.
x = (left blank) to toggle current state.
Sets talk over recovery time.
x = 0 - 5 (seconds)
x = @ Set to default 2 (seconds).
x = ?
to request current state.
Sets program audio ducking amount adjustment.
x = 0 - 40 (0 = minimum ducking; 40 = maximum
ducking)
x = @ Set to default 20.
x = ?
to request current state.