How to Install the Unit
1/4 Bubble
INSIOE
OUTSIDE
FENCE
AWNING
FOAM ..........
COOLED
HEAT
RADIATION
About 1/2"
Over 20"
1, To avoid vibration and noise, make sure the unit is installed securely and firmly
2, Install the unit where the sunlight does not shine directly on the unit.
If the unit receives direct sunlight, build an awning to shade the cabinet,
3, There should be no obstacle, like a fence, within 20" which might restrict heat radiation from the
condenser
4, To prevent reducing performance, install the unit so that louvers of the cabinet are not blocked.
5. Install the unit a little obliquely outward not to avoid leaking the _ndensed
water into the room
(about 1/2" or 1/4 bubble with level).
6. Install the unit with its bottom potion 30~60 '' above the floor level.
7. Stuff the foam between the top of the unit and the wall to prevent air and insects from getting into
the room.
8. The power cord must be connected to an independent circuit. The green wire must be grounded.
9. Connect the drain tube to the base pan hole in the rear side if you need to drain (_nsult
a deaEer )
Plastic hose or equivalent may be connected to the drain tube,
Window Requirements
NOTE: All supposing parts should be secured to firm wood, masonry, or metal.
WINDOW REQUIREMENTS
1 This unit is designed
for installation
in
standard
double hung windows
with actual
opening widths from 26" to 41".
The top and bottom window sashes
must
open sufficiently
to allow a clear vertical
opening of 18" from the bottom of the upper
sash to the window
stool.
B==8
f
.............
l
26° to 41"
18" rain
REPISA
2. The stool offset
(height
behtceen
the stool
and sill) must be less than 1 V4".
#