Download Print this page

LG GR-L247ER Parts List And Instructions Manual page 56

Hide thumbs Also See for GR-L247ER:

Advertisement

CO
roblems
Checks
Measures
High
temperature in
freezer
compartment.
Causes
Cyble
pipe
is clogged.
Check sequence.
1, Check temperature
of condenser
manually,
If it is warm, it is OK.
_eak at loop pipe weld joint
(discharge)
in compressor.
Faulty cooling fan in the compressor
compartment.
- Heat up compressor
discharging
weld joints with touch, disconnect
the pipes, and check the clogging.
Remove the causes of clogging,
If it is not, compressor
discharging
weld, evacuate, and recharge
joints might be clogged.
I the refrigerant.
I=Manu
a''y
c heok whether hot line
I" If it's warm, it's OK. If it's not,
p=pe is warm,
condenser discharging
line weld
If it is warm, it's OK.
]f it is not, condenser outlet weld
joints might he colgged.
Check sequence,
1, Manually checkwhether
condenser is warm, It is not warm
and the frost forms partly on the
evaporator in the freezer
compartment.
Check sequence.
1. Check cooling fan operation.
2. Check that cooling fan is
disconnected from the motor.
joints might be clogged.
Disconnect
with torch, remove the
causes, evacuate, and recharge
seal refrigerant.
Replace the compressor,
weld,
evacuate,
and recharge
refrigerant.
- Replace if motor does not operate.
- If fan is disconnected,
check fan
damage and reassemble
it.
• Refer to fan motor disassembly
and assembly sequence.
Remarks
Direr must be replaced,
Drier must be replaced,