MICOM FUNCTION
Note1) The abnormality of RT-Sensor, R2-Sensor
Icemaker Unit, and Icemaker_Sensor
is not indicated in trouble code but it
is indicated when checking LED (when preasing both freezer temperature
control button and refrigerator temperature
control button for more than 1 second at the same time).
i
RT-Sensor
R2-Sensor
Normal : (_)
LED on,
Normal : (_)
LED on,
Normal : (_
LED on,
Normal : (_)
LED on,
Abnormal : (_) LED Off. --_
Abnormal : (_) LED Off. |
Abnormal:
(_) LED Off. |
Abnormal : (_) LED Off. -j
The rest of LEDs
are all on.
2-16. Test Function
1. The purpose of test function is to check function of the PCB and product and to search for the failure part at the failure
status.
2, Test button is placed on the main PCB of refrigerator
(test switch), and the test mode will be finished after maximum 2
hours irrespective of test mode and then is reset to the normal status.
3. FuncUon adjustment
button is not perceived during performance
of test mode but only warning sounds ring.
4. In finishing test mode, always pull the power cord out and then plug-in it again for the normal state.
5. If nonconforming contents such as sensor failure are found during performance
of test mode, release the test mode and
display the failure code.
6. Even if pressing the test button dudng failure code display, test mode will not be pedormed.
MODE
Test 1
Test2
HANDLING
Press TEST s/w once.
Press TEST s/w once at
TEST1 conditions.
CONTENTS
REMARKS
1. Compressor
continuously
operates.
2. Freezer fan (high speed RPM), Cooling fan
continuously
operates.
3. Defrost heater is off.
4. All display LEDs are on.
5. Stepping motor damper is in open
conditions.
(baffle is open)
1. Compressor
is off
2. Freezer fan, Cooling fan are off.
3. Defrost heater is on.
4. All display LEDs are off. (Freezer room =2"
LED and Refrigerator room "2" LED are
only ON.)
5. Stepping motor damper is in closed. (baffle
is closed).
- Forced operate.
- Freezer fan is off when
door is opened.
- It returns to normal
condi_ons when the
temperature
of defrost
sensor is above 5°C.
- Forced defrost.
Normal
Press TEST s/w once at
Returns to the initial conditions.
Compressor
starts after
Conditions
TEST2 conditions,
seven minutes delay.
-30-

Advertisement

loading

This manual is also suitable for:

Gr-l207er